Renesas 70 Manual De Usuario

Descargar
Página de 162
Chapter 3 Introduction to MR308 
   
- 50 - 
3.5.12 
Alarm Handler Function 
The alarm handler is a time event handler that is started only once at a specified time. 
Use of the alarm handler makes it possible to perform time-dependent processing. The time of day is specified 
by a relative time. Figure 3.41 shows a typical operation of the alarm handler. 
 
Alarm handler 
created 
Activation 
time 
Start 
operating 
Stop 
operating
Handler does 
not start 
Handler starts 
Start 
operating
Activation 
time 
 
Figure 3.41 Typical operation of the alarm handler 
• 
Start Alarm Handler Operation (sta_alm, ista_alm) 
Causes the alarm handler with the specified ID to operational state. 
• 
Stop alarm Handler Operation (stp_alm, istp_alm) 
Causes the alarm handler with the specified ID to non-operational state. 
• 
Reference Alarm Handler Status (ref_alm, iref_alm) 
Refers to the status of the alarm handler. The operating status of the target alarm handler and the 
remaining time before it starts are inspected.