Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series 
Revision January, 2008, Doc. Name: 2007PDD23000007 
 
 
1-49 
Koyo K-Sequence 
A. HMI factory settings 
Baud rate: 9600, 8, ODD, 1 (RS-232). 
Controller station number: 1. 
Control area/status area: R1400 / R1420. 
NOTE
 
1)  If read / write address exceeds the valid range, HMI will stop read/write operation and show  “….Error 
6….. Command Can Not be Executed….” on the screen. 
B. Definition of controller Read/Write address 
Registers 
Read/Write Range 
Register Type 
Format 
Word No. 
Bit No. 
Data 
Length 
Input Status 
Xnnnn 
nnnn: 
0 ~ 1760 (octal) 
N/A 
Word 
Output Status 
Ynnnn 
nnnn: 
0 ~ 1760 (octal) 
N/A 
Word 
Link Relays 
GXnnnn 
nnnn: 
0 ~ 3760 (octal) 
N/A 
Word 
Relays 
GQnnnn 
nnnn: 
0 ~ 3760 (octal) 
N/A 
Word 
Relays 
Mnnnn 
nnnn: 
0 ~ 3760 (octal) 
N/A 
Word 
Stage 
Snnnn 
nnnn: 
0 ~ 1760 (octal) 
N/A 
Word 
Timer Status 
Tnnn 
nnn: 
0 ~ 360 (octal) 
N/A 
Word 
Control Relays 
Cnnn 
nnn: 
0 ~ 360 (octal) 
N/A 
Word 
Special Relay 1 
SPnnn 
nnn: 
0 ~ 760 (octal) 
N/A 
Word 
Register 
Rnnnnn 
nnnnn: 0 ~ 41237 (octal) 
N/A 
Word 
Register 
Pnnnnn 
nnnnn: 0 ~ 37777 (octal) 
N/A 
Word 
¾
  nnnn: Is in octal format and must be the multiple of 16 except for R and P. 
Contacts 
Read/Write Range 
Contact type 
Format 
Word No. 
Bit No. 
Input Status 
Xnnnn 
N/A 
nnnn: 0 ~ 1777 (octal) 
Output Status 
Ynnnn 
N/A 
nnnn: 0 ~ 1777 (octal) 
Linker Relays 
GXnnnn 
N/A 
nnnn: 0 ~ 3777 (octal) 
Relays 
GQnnnn 
N/A 
nnnn: 0 ~ 3777 (octal) 
Control Relays 
Mnnnn 
N/A 
nnnn: 0 ~ 3777 (octal) 
Stage 
Snnnn 
N/A 
nnnn: 0 ~ 1777 (octal) 
Timer Status 
Tnnn 
N/A 
nnn: 
0 ~ 377 (octal)