Amber LED State
Description
3,4
possible system board error
3,5
memory modules are detected, but a memory configuration or compatibility error
3,6
possible system board resource and/or hardware failure
3,7
some other failure with messages on screen
Beep Code
The computer can emit a series of beeps during start-up if the display does not show errors or problems. 
These series of beeps, called beep codes, identify various problems. The delay between each beep is 300 
ms, the delay between each set of beeps is 3 sec, and the beep sound lasts 300 ms. After each beep and 
each set of beeps, the BIOS should detect if the user presses the power button. If so, BIOS will jump out 
from looping and execute the normal shutdown process and power system.
Code
1-3-2
Cause
Memory failure
Error Messages
Error Message
Description
Address mark not 
found
The BIOS found a faulty disk sector or could not find a particular disk sector.
Alert! Previous 
attempts at 
booting this 
system have failed 
at checkpoint 
[nnnn]. For help in 
resolving this 
problem, please 
note this 
checkpoint and 
contact Dell 
Technical Support.
The computer failed to complete the boot routine three consecutive times for the 
same error. Contact Dell and report the checkpoint code (nnnn) to the support 
technician
Alert! Security 
override Jumper is 
installed.
The MFG_MODE jumper has been set and AMT Management features are disabled 
until it is removed.
Attachment failed 
to respond
The floppy or hard drive controller cannot send data to the associated drive.
46