Gateway E-824R Manual De Usuario

Descargar
Página de 116
Appendix A: Logs
www.gateway.com
94
POST failure logs
These events indicate that the autoloader or tape drive detected a failure when 
power was applied. POST may have failed during a reset and retry.
Important
This event type only indicates each time
the test ran and experienced the error
condition.
:
11/00
Unrecoverable Read Error. After 
exhausting the read recovery algorithms, 
the drive was not able to read the data 
correctly.
Problem may be the tape cartridge or the drive.
If the problem continues, contact customer support. 
14/00
Entity Not Found. A logical block that was 
written on the tape was not found while 
trying to read the data.
Problem may be the tape cartridge or the drive. Check drive 
logs to correlate events that may have led up to this 
condition.
If the problem continues, contact customer support.
47/00
SCSI Parity Error. SCSI bus 
communications problem.
Check SCSI cables, terminators, and all devices attached to 
the SCSI bus.
80/01
Cleaning Required
. The drive has 
detected a condition in which a cleaning 
tape must be used. 
Use a cleaning tape or different media. Check drive logs to 
review related events. If this persists with multiple media 
after cleaning, the drive may need to be replaced. If related 
to a single piece of media, replace that tape cartridge.
If the problem continues, contact customer support. 
ASC/ASCQ
Description
Suggested Action
Field
Description
Last Fail
The type of failure that was experienced.