NEC 128/384 Manual De Usuario

Descargar
Página de 154
Page 4-4
NDA-24230 Issue 2.0
Chapter 4
VisuaLink 128/384 User Guide
Connection Procedure
① ~ ➆ indicate the procedure numbers.
① Connect the Video Out  and the audio of the VisuaLink to the Video 
Monitor 
Using the attached video cable, plug one side into the connection marked 
VIDEO 1 IN on the Video Monitor.  Plug the other end into the connection 
marked VIDEO OUT on the VisuaLink.  Using the provided audio cable, 
plug one end into the AUDIO INPUT 1 of the Video Monitor.  Plug the other 
end into the AUDIO OUTPUT of the VisuaLink.
Note:  If a Voicepoint is used do not connect the audio output connection.
➁ Connect the NT1 device to the VisuaLink.
Using the provided data cable (RJ45 - RJ45), plug one end into the VisuaLink 
connection labeled ST/LINE.  The other end of the cable, plugs into the NT1 
device.
Note: If the NT1 device is located more than 300 feet (91 meters) away from 
the VisuaLink,  set the NT1 to have a resistance of 100 
Ω
.  This step 
must be repeated three (3) times for a VisuaLink 384.  NT1 does not 
need to be installed if network terminates in a PBX.  In this case 
connect ST/LINE directly into wall jack.
➂ Connect a microphone to the VisuaLink.
Plug the 3 1/2 mini connector into the VisuaLink connection marked MIC1.
➃ Connect the Video Camera to the VisuaLink.
Using the provided video cable, plug one end into the connection marked 
VIDEO IN on the D30 camera.  Plug the other end of the video cable into the 
VisuaLink connection labeled VIDEO IN 1.
➄ Connect the camera control to the VisuaLink.
With a 8 pin minidin to 8 pin minidin, plug one end into the D30 camera 
connection marked VISCA IN.  Plug the other end into the VisuaLink 
connection marked SERIAL 1.
➅ Connect the camera power.
Plug the Camera AC Power to the AC Power Strip at the bottom of the 
cabinet.
➆ Connect the VisuaLink AC Power.
Using the provided AC transformer power cable, plug the power cable into 
the VisuaLink connection marked DC-IN-5V.  Plug the other end into the AC 
Power Strip.