Installing the SmartSwitch 9000 Module
2-4
Using DIP Switch 6
The purpose of DIP switch 6 is to force a Flash download from a BootP server 
through the EM-EPIM. The Þrst step in this process is to conÞgure the BootP 
server. ConÞgurations of BootP servers can differ from platform to platform and 
from one operating system to another. Read the userÕs manual on BootP and TFTP 
serving for the correct Þles to edit and the correct Þles to execute for the server. 
After conÞguration of the BootP server the module can then have the switch state 
changed on dip switch 6 to initiate BootP and TFTP requests.
When the state of dip switch 6 is changed, the module begins requesting a BootP 
server in an attempt to receive a Flash image download. The modules boot PROM 
initiates a BootP sequence. During this sequence, the module requests an IP 
address and a Þlename from the BootP server. The module then requests a TFTP 
of the Þle and receives the download of the image. The module will not function 
until the Flash image is downloaded from the BootP and TFTP server.
If a BootP and TFTP are not intended at this time, this process may be stopped by 
resetting the module. Resetting is done by pushing the reset button on the 
module, power cycling the chassis, or removing the module from the chassis and 
re-inserting. (See the section titled 
 on page 2-6.) After resetting, 
the module again looks for a BootP server, but will time-out after about four 
minutes. After the time-out, the module boots from Flash memory. The next time 
the power is cycled, the module will boot from Flash memory and not request the 
BootP server.
Installing the Module into the SmartSwitch 9000 
Chassis
To install the SmartSwitch 9000 module, follow the steps below:
1. Remove the blank panel covering the two slots in which the module is being 
installed. All other slots must be covered, if other modules are not being 
installed, to ensure proper airßow and cooling.
2. Attach one end of the ESD wrist strap packaged with the SmartSwitch 9000 
chassis to your wrist. Plug the other end into the ESD Wrist Strap Grounding 
receptacle in the lower right corner of the SmartSwitch 9000 chassis shown in 
Figure 2-2. 
The INB Terminator Modules must be installed on the rear of the fourteen slot 
chassis before powering up this module. The INB Terminator Modules are not 
required on the six slot chassis. Refer to the INB Terminator Modules 
Installation Guide
 for information and installation procedure.
NOTE