Step 3: R3000 Configuration
If you are using 8e6’s R3000 for your Web-access logging device, this step can be per-
formed any time during ER setup, but must be completed in order for the ER to receive 
logs from the R3000. 
A.  Access the Administrator console of the R3000.
B.  Choose the 
Reporting button at the top of the screen to display the Reporting sec-
tion of the Administrator console.
C.  From the navigation panel at the left of the screen, choose Report Configuration to 
display the Report Configuration window.
D.  Select 
8e6 Enterprise Reporter, and then click Save
E.  On the 8e6 Enterprise Reporter tab, in the 
Server field, enter the LAN 1 IP address 
you assigned to your ER (Step 1A: Quick Start menu: administration menu, or Step 
1B, Network Setup: Network Settings, item “C”).
F.   Click 
Add to include this IP address in the Remote Server list box. Your R3000 is 
now set to transfer its log files to your ER via HTTPS. 
NOTE: It is recommended you wait for 1 - 2 hours after the initial installation 
so sufficient data is available for viewing.
You can see if log files have transferred by accessing the ER’s Administrator console 
and choosing 
Tools from the Database pull-down menu to display the Tools screen. 
Choose the 
File Watch Log and click View. The transfer is working if you see an en-
try that includes the date, time, and IMPORTING: shadow.log.machine1. The transfer 
should occur every hour. Once you see an entry, reporting information will be available 
one hour after the timestamp of the import listing.