Renesas M32192T2-PTC Manual De Usuario

Descargar
Página de 6
 
(3/6)
 
5. Connection Procedure 
 
 
5.1 For the M32100T-SDI-E, or M32170T-SDI. 
(1)  Mount the NQPACK144SD on the user system 
(2)  Connect the YQPACK144SD on the NQPACK144SD. 
(3) Secure the four corners of the YQPACK144SD with the 
YQ-GUIDE’s. 
(4)   Mount the M32192T2-PTC on the YQPACK144SD. 
(5)   Set the clock select switch. 
(6)  Mount the M3T-PTC-CNV on the M32192T2-PTC. 
(7) Connect the emulation pod probe to the M32192T2-PTC 
via the SDI MCU control interface cable and the SDI trace 
interface cable. 
 
 
 
 
 
 
(7) 
M32192T2- PTC  
YQPACK144SD 
YQ-GUIDE(x4)
NQPACK144SD
 
 
144-pin 0.5mm pitch 
(144P6Q-A) foot pattern
 
(1)  
(2)  
(3)  
(4)  
Clock select switch
 
(5)  
(6) 
●  : No.1 pin
 
Be sure to match the position of No. 1 pin of the foot pattern and each part.
 
M3T - PTC - CNV
(separately available)
 
Connection to the M32100T-SDI-E or  M32170T-SDI
Interface cables of the pod probe
 
Figure 5.1 Connection Procedure(1)