Sharp LC-M3700 Manual De Usuario
![Sharp](https://files.manualsbrain.com/attachments/09c3752719497cddb7682a2870f2b01d664ac839/common/fit/150/50/128db0ff9ffd18d046ef9a246eb7bdc77b15206699c58d5f48a715e1dba1/brand_logo.png)
43
US
PC Operation
<Response format in Advanced operation >
■ Normal response
1Response when no ID number has been set.
O
Carriage return code
(0D
(0D
H
, 0A
H
)
K
↵
A response is returned when execution of the
pertinent command is finished.
pertinent command is finished.
2Response when an ID number has been set.
O
ID number of
responding monitor
Carriage return code
(0D
(0D
H
, 0A
H
)
K
SPC
0
0
1
↵
Space (20
H
)
■ When a command has not been executed correctly*
1Response when no ID number has been set.
E
Carriage return code
(0D
(0D
H
, 0A
H
)
R
R
↵
2Response when an ID number has been set.
E
Carriage return code
(0D
(0D
H
, 0A
H
)
R
R
SPC
0
0
1
↵
ID number
Space (20
H
)
* This is returned when there is no such command, or when the command cannot be used in the
current state of the monitor (i.e. video auto-adjustment with video display).
* If communication has not been established for reasons like a bad connection with the monitor,
nothing is returned (not even ERR).
* If no monitor has been assigned the designated ID number (e.g. if the command IDSL0002[X] is
issued, but no monitor with ID=002 is found), ERR
XXX[X] is returned.
Continued on the next page.
PC Operation (Continued)
(ID number at the furthest end)
In the above case
IDSL0004
IDSL0004
←Non-existent ID number
WAIT
ERR 003
ERR 003
←Monitor with ID=3 at the furthest end returns ERR
PC
Set 1
Set 2
Set 3
[Example]