Black Box VX-HDMI-IP-UTX Manual De Usuario

Descargar
Página de 44
724-746-5500   |   blackbox.com 
Page 27
Chapter 5: Advanced Commands
To override the DIP rotary switch, use the commands shown on the next page for 
each device:
NOTE: B0, B1, B2, and B3 refer to the values in Table 5-1.
5.2.1 Transmitter
To change the multicast group IP, type in:
astparam s multicast_ip 225.0.B0.B1B2B3
To change the hostname ID of the transmitter, type in:
astparam s hostname_id B0B1B2B3
ast_send_event -1 e_chg_hostname
To override DIP rotary switch setting on bootup:
astparam s reset_ch_on_boot n 
(space between boot and the n)
 
astparam save
 
reboot
5.2.2 Receiver
To change the multicast group IP, type in:
astparam s multicast_ip 225.0.B0.B1B2B3
To change the transmitter channel read:
astparam s ch_select B0B1B2B3
To override DIP rotary switch setting on bootup, type in:
astparam s reset_ch_on_boot n 
(space between boot and the n)
astparam save
reboot
5.3 Serial Extension
Serial extension can be done from one transmitter to all receivers linked. Telnet serial 
extension is also available as a replacement of serial. Serial extension information:
Default baud rate: 9600   
(unless changed manually)
Data bits: 8
Parity: Even
Stop bits: 1