Regency U32S-LP5 Manual De Usuario

Descargar
Página de 36
25
U32S-5 FPI Direct Vent Gas Insert
FAN MAINTENANCE
If your fan requires maintenance or replacement, access to the fan is 
through the plate on the rear wall of the fi rebox. NOTE: the unit MUST 
NOT be operated without the fan access panel securely in place.
Caution: Label all wires prior to disconnecting when servicing 
controls. Wiring errors can cause improper and dangerous 
operation. Verify proper operation after servicing.
MAINTENANCE
1)  Turn the unit off and allow it to cool down to room temperature.
2)  Disconnect the power source and turn off the gas supply to the
 insert.
3)  Open the bottom louver.
4)  Remove the door frame by lifting out from the bottom and lift up off 
the glass door.
5)  Remove the glass door.
 
a)  Remove the 2 hooks shown below at the bottom of the glass  
 
     door
 b) 
 
Swing the door out 45
o
 from the bottom and lift up and  
 
      out.
7)  Remove the burner by undoing the 2 screws shown. 
           a)  Carefully slide the burner to the left.  
         
          b)  Then lift the burner up and out carefully, ensuring not to spill       
          the glass crystals.
Door Frame
Glass Door
Burner
FAN REMOVAL