Goodman Mfg GAS-FIRED WARM AIR FURNACE Manual De Usuario

Descargar
Página de 56
49
*MH95[0453,0704,0905D]
*MH95[0703,0904,1155]
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
WIRING DIAGRAM
H
IG
H
 V
O
LTA
G
E
!
D
IS
CO
NNE
CT
 
AL
L
 
PO
WER
 
BE
F
O
RE
 
SE
R
V
IC
IN
G
 
OR
 
IN
S
T
A
LLI
N
G
 
TH
IS
 
UNI
T
.  
M
U
LTI
P
L
E
 
PO
WER
 
S
O
U
RCE
S
 
MA
Y
 
BE
 
PR
E
S
EN
T
. F
AIL
U
RE
 
TO
 
DO
 
SO
 
MA
Y
 
CAU
S
E
 
PR
O
P
E
R
T
Y
 
DAM
AG
E
P
E
RS
O
NAL
 
INJ
URY
 
OR
 
DE
AT
H
.
R
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
COLOR CODES:
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
0140F00663 REV. A
 OR (MED LOW)
 BL (MED)
 RD (LOW)
GAS VALVE (HONEY WELL)
C
PM
C
G
W
       INTERNAL TO
INTEGRATED CONTROL
JUNCTION
EQUIPMENT GND
FIELD GND
DIAGNOSTIC
LED
2 CIRCUIT 
CONNECTOR
HOT
SURFACE
IGNITER
 OVERCURRENT
PROT. DEVICE
IGNITER
TH (3)
INTEGRATED 
CONTROL MODULE
JUNCTION BOX
LINE-H
IN
T
E
G
R
A
T
E
D
 CO
NT
RO
L
 M
O
DUL
E
GND
DISCONNECT
L
N
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE
PROPERLY
POLARIZED
AND GROUNDED.
OVERCURRENT PROTECTION DEVICE
BR
GY
RD
BL
BK
4. IF  HEATING AND COOLING  BLOWER SPEEDS ARE NOT THE SAME, DISCARD JUMPER BEFORE CONNECTING BLOWER LEADS.  UNUSED
    BLOWER LEADS MUST BE PLACED ON "PARK" TERMINALS OF INTEGRATED CONTROL OR TAPED.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL
HAVING A TEMPERATURE RATING OF AT LEAST 105
TERMINAL
SWITCH (PRESS.)
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
PK PINK
115 VAC HOT AND PARK TERMINALS
LINE-H
FLAME 
SENSOR
FRONT COVER
PRESSURE SWITCH
( SINGLE CONTROL ON 45K BTU )
N
O
C
GY
BK
PLUG CONNECTION
FIELD SPLICE
SWITCH (TEMP.)
OR
24V THERMOSTAT
CONNECTIONS
GR
GND
115 VAC
24 VAC
BLOWER 
COMPARTMENT 
DOOR SW ITCH
(OPEN WHEN 
 DOOR OPEN) 
DOOR
SWITCH
WARNING:DISCONNECT POWER BEFORE 
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
BK
GND
DISCONNECT
L
PO
W
E
R
 SU
PPL
Y
 W
IT
H
O
V
E
R
C
URRE
N
T
 P
R
O
T
E
C
T
IO
N
D
EVI
C
E
WH
JUNCTION
 BOX
 OR
ID BLOWER 
PRESSURE 
SWITCH
HEAT-H
GND
WH
RD
WH
GND
BURNER COMPARTMENT
BLOWER COMPARTMENT
NOTE 4
SEE
N
O
COOL-H
 BK (HI)
BR
BR
CAPACITOR
YL
WH
YL
CONTROL
PRIMARY LIMIT
AUTO RESET
BL
PU
MANUAL RESET ROLLOUT LIMIT CONTROL(S)
 RD
OR
PK
BK
WH
WH
BLOWER
INDUCED DRAFT
MANUAL RESET
AUXILIARY LIMITS
(1) IN UPFLOW
      BLOWER DECK
(2) IN C'FLOW 
      BLOWER HOUSING
C
CIRCULATOR 
BLOWER
FS
LIMIT CONTROLS
MANUAL RESET AUXILIARY
HI
 
HE
AT
-H
LO
 
HE
AT-H
IGNITER
HOT SURFACE
IND
IGN
EAC-H
AIR CLEANER
ELECTRONIC
BLWR
CIRCULATOR
BLWR
ID
FLAME SENSOR
115 VAC
TRANSFORMER
40 VA
24 VAC
GND
CONTROL
LIMIT
PRIMARY
AUTO RESET
(SINGLE CONTROL ON 45K BTU)
LIMIT CONTROL(S)
MANUAL RESET ROLLOUT
RO1 (5)
RO2 (11)
HLO (1)
HLI (7)
MVC (9)
GND (8)
BL
YL
OR
RD
GR
BR
PK
GY
BK
MICRO
TO
C
G
Y
W
R
TRANSFORMER
40 VA
2
WH
OR
BL
YL
OR
OR
GY
PK
RD
OR
GY
XF
M
R
-H
TE
R
M
IN
A
L
S
GY
OR
GR
BR
1
2
3
12
11
10
9
8
7
6
5
WARNING: 
C. USE COPPER CONDUCTORS ONLY.
24 VAC
HUMIDIFIER
24 VAC
HUMIDIFIER
HUMIDIFIER
PSO (4)
MVL(2)
PS (10)
C
NO
C
NO
FRONT COVER
PRESSURE SWITCH
ID BLOWER
PRESSURE
SWITCH
0
C
7
6
5
4
3
2
1
OFF               = CONTROL FAILURE
   STEADY ON = NORMAL OPERATION
   1 FLASH       =
   2 FLASHES  = PRESSURE SWITCH STUCK CLOSED
   3 FLASHES  = PRESSURE SWITCH STUCK OPEN
   4 FLASHES  = OPEN HIGH LIMIT
   5 FLASHES  = FLAME SENSE WITHOUT GAS VALVE
 OPEN ROLLOUT OR OPEN FUSE
   7 FLASHES  = LOW FLAME SIGNAL
   6 FLASHES  =
SYSTEM LOCKOUT (RETRIES EXCEEDED)
   CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY
CONTROL
MODULE
INTEGRATED
FUSE
ON
OFF
2ND 
STAGE 
DELAY
MODE
HEAT 
OFF 
DELAY
FS
1
3
2
HI
PM
GAS
VALVE
C
HI
MVH (12)
FACTORY SETTINGS 
SHOW N
*
*
*
*
SEE 
NOTE 6
COOL-H
TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH
PU
Y
6. TO RECALL THE LAST  5 FAULTS, MOST RECENT TO LEAST  RECENT,  DEPRESS  SWITCH FOR MORE THAN  2  SECONDS  WHILE IN
     STANDBY (NO THERMOSTAT INPUTS)
8
GY
BK
WH
BK
TR (6)
XFMR-H
4
N
T
O
 115
 V
A
C /
 1
Ø
 / 6
0
HZ
1
PK
WH
WH
WH
 OR
   8 FLASHES  = CHECK IGNITER OR IMPROPER GROUNDING