CFM UVHK29MN Manual De Usuario

Descargar
Página de 20
5
20008056
WARNING
This appliance is for installation in a solid-fuel 
burning masonry, fireplace with a working flue, 
a U.L.-127 listed manufactured solid-fuel burn-
ing fireplace, in any Majestic ventless firebox, 
or in any listed ventless firebox enclosure 
certified to I.A.S. U.S. Requirement 2-97 or 
ANSI Z21.91.
NOTICE
This is an unvented gas-fired heater. It uses air 
(oxygen) from the room in which it is installed. 
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Pages 7 and 8. 
Installation Requirements
The fireplace must meet the minimum dimensions listed below. (Fig. 1) Do not install the logset if the fireplace does 
not meet these minimums. 
Pressure Test Points
The gas control is equipped with a captured screw-type 
pressure test point, therefore it is not necessary to pro-
vide a 1/8” test point upstream of the control.
Odor During Operation
Neither natural gas nor propane gas give off an odor 
when burned. The nature of a vent free combustion 
system, however, is such that odors may occasionally 
be produced during heater operation when impurities 
exist in the immediate area. Cleaning solutions, paint, 
solvents, cigarette smoke, candles, adhesives, new car-
pet or textiles, etc., all can create fumes. These fumes 
may mix with combustion air and can create odor. Such 
odors will disappear over time, however, the condition 
can be alleviated by opening a window or otherwise 
providing additional ventilation to the area.
A. Front width                 B. Rear width
C. Depth                         D. Height
Fig. 1  Minimum fireplace dimensions.
FD370-2
Fireplace 
dimensions/vl18
3/25/99
A
B
D
C
FD370-2
High Elevations
Input ratings are shown in BTU per hour and are 
certified without deration from elevations up to 
4,500 feet (1,370m) above sea level.
Nuisance outages may occur at altitudes above 
4,500 feet (1,370m) if dirt, dust, lint and/or cob-
webs are allowed to accumulate on burner and/or 
ODS pilot. Monthly inspection and cleaning is 
recommended for altitudes above 4,500 feet 
(1,370m)
For elevations above 4,500 feet (1,370m) in USA, 
installations must be in accordance with the 
current ANSI Z223.1/NFPA 54 and/or local codes 
having jurisdiction.
In Canada, please consult provincial and/or local 
authorities having jurisdiction for installations at 
elevations above 4,500 feet (1,370m)
 
Min. Fireplace Dimensions 
 
 
 
 
 
 
 
BTU/hr.            
  Logset 
Gas 
Front  Rear  Overall  Overall     Pressure (w.c.) 
Manifold  
Low 
Med.  
High  Air Shutter 
 
 
Width  Width  Depth  Height 
Min.    Max. 
Pressure 
Input 
Input 
Input 
Setting
  UVHK36MN  Natural 
28” 
18” 
14¹⁄₂” 
17” 
5.5”    14.0” 
3.5” 
10,000  22,500  36,000  .136” (1)
  UVHK31MP  Propane  28” 
18” 
14¹⁄₂” 
17” 
11.0”    14.0” 
11.0” 
10,000  20,000  31,000  .136” (2)
  UVHK29MN  Natural 
23” 
16” 
14¹⁄₂” 
17” 
5.5”    14.0” 
3.5” 
16,000 
-- 
29,000  .136” (1)
  UVHK23MP  Propane  23” 
16” 
14¹⁄₂” 
17” 
11.0”    14.0” 
11.0” 
14,000 
-- 
23,000  .136” (2)
  Inlet Supply