20 
Fans 
The 
3-Slot Desktop Chassis
 includes temperature-triggered fans.  When the temperature of the 
chassis reaches 40° C, the two fans activate to cool the chassis.  The fans’ operation can be tested 
by holding the Alarm Reset Button down for 4 to 5 seconds.  The fans will activate and then they 
will turn off when the button is released.  If the fans do not activate, contact Black Box.  Fans are 
not end-user replaceable. 
The red Alarm Reset Button also functions as a Fan Test button.  To verify fan functionality, hold 
the button down for several seconds, the fans should engage.  The fans will turn off when the 
button is released.  
Installing Management and Application Modules 
SNMP Management Modules include two twisted pair ports, one for management and one 
reserved for future use.  The Management Module also features a DB-9 serial port, and 
supports SNMP V1/V2c. 
Installing Applications Modules 
To install a module: 
1.  Remove the blank bracket (if present) covering the slot where the module will be 
installed.  Black Box recommends installing blank brackets in unused module slots. 
2.  Slide the module into the chassis using the card guides. 
3.  Secure the module to the chassis by tightening the captive screw.  (Refer to the 
documentation shipped with the module for configuration information.) 
In order to manage a Desktop Chassis, the SNMP Management Module needs to be installed 
in the appropriate slot of the chassis.    
•  Install the 3-Slot Desktop Chassis slot SNMP Management Module into the  
bottom 
left slot. 
 
NOTE 
This slot is ONLY for the Management Module; do not install Application Modules such as 
media conversion and mode conversion modules in this slot.