Escali E30CBB Manual De Usuario

Descargar
Página de 12
■ Procedures to set up time to automatically turn off the power   
Push the “C” key for 5 seconds while the weight, quantity, unit weight    of the scale are zero state and Tare is released as the picture No. 1.
 
W eighing range : 40 g ~  6/15 kg, e = d : 2 g / 5 g 
                        (0.1 lb ~  15/30 lb, e = d : 0.005 lb/0.01 lb)
lb
Model : CB-15N
WEIGHT  
 
                                      
UNIT WEIGHT
                                    
QUANTITY
                                    
BAT
  Short
Unit Wt.
TOTAL
TARE
ZERO
Short
Q'ty
kg
g/pc
pcs
 
Set up the preferable time to turn off the power by using the “+” key or “=” key while the display is showing as picture No. 2. 
W eighing range : 40 g ~  6/15 kg, e = d : 2 g / 5 g 
                        (0.1 lb ~  15/30 lb, e = d : 0.005 lb/0.01 lb)
lb
Model : CB-15N
WEIGHT  
 
                                      
UNIT WEIGHT
                                    
QUANTITY
                                    
BAT
  Short
Unit Wt.
TOTAL
TARE
ZERO
Short
Q'ty
kg
g/pc
pcs
 
Complete the procedures to set up the time using the “M” key.    Not pushing the “M” key does not save this function.   
z
  The scale is automatically turned off when not being used for selected time without inputting a key or changing the weight. 
z
  Used in order to prevent unnecessary consumption of the battery. 
z
  Select time to automatically turn off the power as OFF – 5min.- 10min. – 30min. – 60min. – 120min. 
z
  Release the time setup by setting up with ‘OFF’.   
z
  Without inputting a key for 5 seconds will automatically set back to the scale mode in the picture No. 2.   
z
  The scale is dispatched with ‘5 minutes automatic turning off the power’ mode. (The scale is automatically turned off when not being used for 5 minutes.) 
 
 
7.  Error Indication and its Information 
 
Error Information 
Solution 
Error 
Information 
Solution 
Err-01 
Memory reading error 
A/S 
Err-02 
Zero range error (Test mode) 
A/S 
Err-03 
Problems in Weighing range (Test mode) 
A/S 
Err-d0 
Exceed maximum weight 
Check the platform, A/S 
Err-d1 
Below minimum weight 
Check the platform 
Err-d2 
Problems in AD converter 
A/S 
Err-d3 
Tare range error: Unstable condition, Exceed 
tare range, Setting up the Tare during “-
(minus)“ weighing 
Check the scale 
Err-d4 
Exceed maximum data range of AD 
converter 
Check to see if there is anything 
on the platform, A/S 
Err-d5 
Below minimum data range of AD converter 
Check the platform, A/S 
Err-d6 
Weighing range error 
A/S 
Err-d7 
Problems in Zero / Exceed the range 
A/S 
Err-d8 
Not in a stabilized condition 
The 
scale 
is 
experiencing 
vibrations or wind currents : Place 
the scale in a stabilized condition 
 
- When the scale stops operating or ON/OFF key does not operate 
- Reset the battery or adapter jack.    When they do not operate after resetting the battery or adapter jack, claim the after service.