DVMRe Triplex 
Ten and Sixteen-Channel Units 
Password 
Type 
Access 
Level 
Function 
Changeable 
by user? 
Default 
Password 
Operator  Operator 
Provides access to the Operator 
and SystemView menus. 
Yes 
Press ‘ENTER’ 
4 Times 
Installer 
Installer 
Provides access to all on-screen 
menus. 
Yes 
3 4 7 7 
Factory 
Defaults 
Installer 
Resets the multiplexer to the 
factory defaults (except the time, 
date, email addresses, and email 
IP address). 
No 
8 1 1 1 
Language  Installer 
Provides access to the On-screen 
Language menu. 
No 
5 4 1 5 
Ethernet 
Access 
Reset 
Installer 
Deactivates the ethernet 
password, so that the unit may be 
accessed by any PC equipped with 
WaveReader. 
No 
1 1 1 1 
1.4  Unpacking 
Check the package and contents for visible damage.  If any components are damaged or missing, do 
not attempt to use the unit, contact the supplier immediately.  If the unit must be returned, it must be 
shipped in the original packing box. 
Package Contents 
• 
The DVMRe Triplex unit. 
• 
The Alarm Interface Circuit Board (P/N 0090-0077). 
• 
Accessory PCB (P/N 0900-0127). Audio equipped models only. 
• 
The User Manual (P/N 0150-0193). 
• 
A WaveReader Software CD (P/N 0151-0005-25W11). 
• 
The WaveReader Software Manual (P/N 0150-0143). 
• 
The Archiving Addendum (P/N 0150-0194). 
• 
WaveWatch User Manual (P/N 0150-0189). 
• 
Power Supply (P/N 4310-0020). 
• 
Power Cords (120 VAC P/N 4310-0002) and (220 VAC P/N 4310-0001). 
  
1.5  Installation Environment 
Power:  Ensure that the installation site’s AC power is stable and within the rated voltage of the 12 
Volt DC power supply.  If the site’s AC power is likely to have spikes or power dips, use power line 
conditioning or an Uninterruptable Power Supply (UPS). 
Ventilation:  Ensure that the location planned for the installation of the unit is well ventilated.  Take 
note of the locations of the cooling vents in the unit’s enclosure, and ensure that they are not 
obstructed. 
Temperature:  Consider the unit’s operating temperature (0 to 40 °C) and non-condensing humidity 
specifications (10% to 80%) before choosing an installation location.  Extremes of heat or cold beyond