Fostex D2424 Manual De Usuario

Descargar
Página de 147
45
Model D2424  Reference Manual (Recording Digital Data) 
Selecting a recording Program
1. If you already have multiple Programs, select the
desired Program using the Program Select
function.
* See page “
35
” for more information on the Program
Select function.
Setting the digital input
Set up the digital signal to be input and the digital in
clock at the setup mode “Setup of digital inputs”
menu.
The setting of digital input is initially set to “Analog”
and digital signals cannot be input.
In order to record external digital signals, “SP DIF
Async,” “SP DIF Sync,” “adat Async” or “adat Sync”
should be setup in accordance to the purpose.
<Notes>
• Do not connect or disconnect the optical cable to
the [DATA INPUT] jack when digital input is assigned.
Doing so could generate noise in the D2424 and
affect the external digital equipment.
• When the digital input is set to “adat” (Async or Sync)
and locked to any one among the three [DATA IN
PUT] (1-8, 9-16, 17-24), “DIGITAL” will light in the
display, and the tracks not locked will automatically
change to analog input.
By using this function, analog/digital 24 track
simultaneous recording will be possible by applying
analog signals to tracks 1-8 and adat digital signals
to tracks 9-16 and 17-24.
Setting recording tracks
Press the RECORD TRACK select keys of the tracks
selected in the digital input track menu to ready the
tracks for recording.
Recording
1. Locate the beginning of the Program.
2. Make sure that the [DIGITAL] indicators light up
on the screen. While pressing and holding down
the [RECORD] button, press the [PLAY] button to
start recording.
3. Play the external digital device.
Make sure that the level meter segments light up and
move as the digital signal is being input.
Completing recording
4. After you finish recording, stop the recorder and
the connected digital equipment.
"SPDIF:Async":
S/P DIF digital signals from [DATA INPUT 1-8] will
be assigned to tracks 1 and 2, and the digital equip-
ment is synchronized with the internal clock of the
D2424.
"SPDIF:Sync":
S/P DIF digital signals from [DATA INPUT 1-8] will
be assigned to tracks 1 and 2, and will be synchro-
nized with the S/P DIF digital signals from the exter-
nal digital equipment.
"adat:Async"
adat digital signals from [DATA INPUT 1-8], [9-16]
and [17-24] will be assigned to tracks 1-8, 9-16 and
17-24 respectively, and the digital equipment syn-
chronized with the internal clock of D2424.
"adat:Sync"
adat digital signals from [DATA INPUT 1-8], [9-16]
and [17-24] will be assigned to tracks 1-8, 9-16 and
17-24 respectively, and synchronized with the adat
digital signals from the external digital equipment.
* Refer to page “117” for setup of [D.in?].
If digital input is set to "Analog," "SPDIF Async" or
"adat Async," the SETUP mode "Clock Sel?" (setup
of operating clock) must be set up.
<Note>
When the “Setup of digital inputs” is set to sync mode
of “SPDIF sync” or “adat Sync”, the SETUP mode "Clock
Sel?" setting will be ignored and the digital-in clock
will have priority.  In this case, "DIGITAL" and "EXT"