OUTPUT PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
CAUTION
Engine  will  not  idle  down.    Weld
and auxiliary outputs are normal.
1. Check that the engine switch is
in the “Auto” position.
2. Check that the engine choke is
fully open.
3. There  may  be  a  load  on  the
weld  or  auxiliary  output.
Disconnect all cables and cords.
1. The  idle  solenoid  may  be
improperly  adjusted.    Perform
the  Engine  RPM  adjustment
procedure
.
2. With the engine running, place
the engine switch in the “Auto”
position.    Check  for  battery
voltage  at  the  idle  solenoid,
lead 213B.  if battery voltage is
not  present,  check  engine
switch,  connector  P4/J4,  and
leads 213A and 213B.
3. If battery voltage was detected
in  step  #2  above,  check
connector  P4/J4,  leads  215
and 215A.
4. Check for AC voltage at leads
260  (J2-3)  and  261  (J2-4).
With no load on either the weld
or  auxiliary  output,  the  meter
should  read  about  26  mV.    If
the  voltage  is  significantly
higher  than  this,  the  toroidal
current  transformer  may  be
faulty,  or  improperly  wired.
This  may  also  indicate  a  load
on  machine  input  or  faulty
internal  components  drawing
current.
5. If  the  above  readings  are
normal, replace the PC board.
TROUBLESHOOTING AND REPAIR
F-7
F-7
OUTBACK® 185
Engine idles own but will not stay
at low idle.
Low idle ROM may be set too low.
Perform  the  engine  RPM
adjustment procedure
.