Grizzly G0637 Manual De Usuario

Descargar
Página de 60
-42-
G0637/G0638 Cyclone Dust Collector
Dust Collector Operation
Symptom
Possible Cause
Possible Solution
Loud, repetitious 
noise, or excessive 
vibration coming 
from dust collector.
1.  Dust collector is not on a flat surface and 
wobbles.
2.  Impeller is damaged and unbalanced.
3.  The motor mounting or housing 
connections are loose.
4.  Impeller is loose on the motor shaft.
5.  Motor fan cover is dented, causing the 
motor fan to hit the cover while spinning.
1.  Stabilize the dust collector.
2.  Disconnect dust collector from power, and inspect 
the impeller for dents, bends, loose fins. Replace 
impeller if any damage is found.
3.  Make sure all fasteners on the dust collector are 
tight.
4.  Replace the motor and impeller as a set if the 
motor shaft and the impeller hub are damaged.
5.  Replace motor fan cover.
Dust collector does 
not adequately 
collect dust 
or chips; poor 
performance.
1.  Dust collection bags are full.
2.  Filter is dirty.
3.  There is a restriction in the duct line.
4.  The dust collector is too far away from 
the point of suction, or there are too many 
sharp bends in the ducting.
5.  The lumber is wet and dust is not flowing 
through the ducting smoothly.
6.  There is a leak in the ducting, or a series 
of small leaks, or too many open ports.
7.  There are not enough open branch lines at 
one time, thereby causing a velocity drop 
in the main line.
8.  The ducting and ports are incorrectly 
sized.
9.  The machine dust collection design is 
inadequate.
10. The dust collector is too small for the dust 
collection system.
1.  Empty collection bags.
2.  Clean filter.
3.  Remove dust line from dust collector inlet and 
unblock the restriction in the duct line. A plumbing 
snake may be necessary.
4.  Relocate the dust collector closer to the point of 
suction, and rework ducting without sharp bends. 
Refer to 
Designing the System, beginning on 
Page 28.
5.  Process lumber with less than 20% moisture 
content.
6.  Rework the ducting to eliminate all leaks. Close 
dust ports for lines not being used. Refer to 
Designing the System beginning on Page 28 for 
more solutions.
7.  Open 1 or 2 more blast gates to different branch 
lines to allow the velocity in the main line to 
increase.
8.  Reinstall correctly sized ducts and fittings. Refer to 
Designing the System beginning on Page 28 for 
more solutions.
9.  Use a dust collection nozzle on a stand.
10. Install a larger dust collector to power your dust 
collection system.
Sawdust being 
blown into the 
air from the dust 
collector.
1.  Duct clamps or dust collection bags are 
not properly clamped and secured.
2.  Cylinder or funnel seals are loose or 
damaged. 
1.  Re-secure ducts and dust collection bag, making 
sure duct and bag clamps are tight and completely 
over the ducts and bags.
2.  Retighten all mounting and sealing points, replace 
damaged gaskets.