4.5.1.11  Timer Settings
T1 Timer
Description
Selects the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
250
500
1000
2000
4000
Default Value
500
Configuration File Reference
T2 Timer
Description
Selects the maximum interval, in seconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
2
4
8
16
32
Default Value
4
Configuration File Reference
Timer B (milliseconds)
Description
Specifies the value of SIP timer B (INVITE transaction timeout timer),
in milliseconds. For details, refer to RFC 3261.
Value Range
250–64000
Default Value
32000
Configuration File Reference
Timer D (milliseconds)
Description
Specifies the value of SIP timer D (wait time for answer resending), in
milliseconds. For details, refer to RFC 3261.
Value Range
0, 250–64000
Default Value
5000
Configuration File Reference