Specifications
 General Description
 Characteristics
Notice:
The power supply voltage of the main unit may differ from the values described in the table 
above depending on the suffix of the model number, please consult your dealer for detailed 
information.
Item
Description
System Capacity
CO lines
Stations
192 max.
448 max.
Power Supplies
Primary
Secondary
Power Failure
220-240 V AC, 50/60 Hz
Station Supply Volt: 30 V
Circuit 
Volt: 5 
V, 15 
V
Memory backup duration: seven years with a 
factory-provided lithium battery
Power Failure Transfer function is provided.
System operation for about four hours using 
recommended batteries (consisting of two 12 V 
DC 40 Ah Automobile-type batteries)
Dialling
Outward/Internal
Mode Conversion
Dial Pulse (DP) 10 pps, 20 pps, Tone (DTMF)
Dialling
DP-DTMF, DTMF-DP
Connector
CO lines
ISDN lines
Stations
Paging Output
External Music Input
Amphenol Connector
Modular Jack (RJ45)
Amphenol Connector
Pin Jack (RCA JACK)
Two-conductors Jack
(MINIJACK 3.5 mm in diameter)
SMDR
(Station Message 
Detail Recording)
Interface
Output Equipment
Detail Recording
Serial Interface (RS-232C)(D-SUB, 25-pin)
Printer/Personal Computer
Date, Time, Extension Number, Outside Line 
Number, Dialled Number, Ring Duration, Call 
Duration, Account Code, Caller ID, Timed Reminder
Item
Description
Maximum Number of Station 
Instruments per Line
1 or 2 by Parallel or eXtra Device Port Connection of a 
Proprietary Telephone and a Single Line telephone
Ring Voltage
75 Vrms at 25 Hz depending on the ringing load
Environmental Requirements
0 - 40 ° C, 10 - 90 % relative humidity