2.2 Installing the Advanced Hybrid System
Installation Manual
31
2.2.6
Connecting Backup Batteries
Backup batteries and a backup battery cable (KX-A227) provide a backup power supply to allow full 
use of the PBX in the event of a power failure. In a power failure, the backup batteries automatically 
maintain the power for the PBX without interruption.
1.
Set the Power Switch of the PBX to the "OFF" position and disconnect the AC cord from the AC 
outlet.
2.
Connect the backup battery cable with 2 identical VRLA (Valve Regulated Lead Acid) batteries 
(12 V DC × 2).
Turn on the power switch of the PBX only after the installation of the PBX is finished and AC cord 
is plugged into the AC outlet.
For each backup battery, battery capacity of 14 Ah or below is recommended (otherwise, the 
battery charge may not be maintained).
Make sure that the type and capacity of the 2 backup batteries are identical.
The backup battery cable should not be exposed to direct sunlight. Keep the backup battery 
cable and the backup batteries away from heating appliances and fire. Place the backup batteries 
in ventilated place.
For details about the backup batteries, refer to the manual intended for the batteries.
CAUTION
Be sure to comply with all applicable laws, regulations, and guidelines.
Make sure that the polarities of the backup batteries and wiring are correct.
Make sure that you do not short the backup batteries or cables.
When replacing one of the batteries, use only the same or equivalent battery type 
recommended by the battery manufacturer. There is a danger of explosion if the backup 
batteries are incorrectly replaced.
 
Dispose of used batteries according to the manufacturer's instructions.
The charging time of your battery varies depending on the charge remaining, the 
characteristics of the battery charger, and the ambient temperature. 
 
Refer to the instructions provided by the battery manufacturer for details. 
 
The following is an example calculation of the time needed to charge a drained battery 
(Battery rating: 24 Ah) connected to the PBX:
Fuse
Backup Batteries  (12 V DC x 2)    
Battery  Interface
Backup Battery Cable
Connector
Red
Black