TERMINAL CONNECTION
2.8.1
Requirements for Connecting Programming Terminal
The programming terminal must be connected with a serial cable with an RS-232C connector 
at the EIA port. This must be a null modem cable. This enables system administration (system 
setup, mailbox setup, and system diagnosis) to be performed.
Communication parameters of the VPS have been set to the following values at the factory:
2.8.2
Connecting the RS-232C Cable
STOP:
Before connecting the cable, make sure the power switches on both the data terminal and 
the VPS are OFF.
Insert the RS-232C cable into the VPS with the connector indicating the same direction.
The cable must be shielded and no longer than 2m {6.5 feet}.
Table 6 
COMMUNICATION PARAMETERS
Baud Rate:
9600 bps
Word Bit Length:
8 Bits
Parity:
None
Stop Bit Length:
1 Bit