Chapter 3. Cabinet Installation
 Section 300-Installation
3-18
DBS Manual - Revised April 2000
DBS-2.3/9.2-300
Test Phone
Guidelines
• The test terminal (CN3) on the DBS Connector Panel can be used to 
connect a display phone for programming. 
The test terminal can be used for initial programming before extension 
cabling is completed.
• The test terminal is turned on by flipping SW1 on the Connector Panel to 
the “Test” position. When SW1 is in the test position, extension ports 7 
and 8 are connected through the test terminal. When SW1 is not in the test 
position, extension ports 7 and 8 are connected through the MDF.
Note: Before using the test terminal on a DBS that is operational, be sure  
the phones connected to ports 7 and 8 can be taken out of service. 
• A DSS/72 can be connected to the display phone for text entry. Port 7 must 
be assigned as extension 101 and the DSS/72 must be assigned as 
telephone type 13 for the DSS/72 to operate.
Installation
1.  Connect the telephone and DSS (optional) to CN3 on the Connector 
2.  Set SW1 to “Test.”
3.  When programming is completed, set SW1 back to “ST.”