Chapter 4. Trunks and Lines
 Section 300-Installation
4-44
DBS Manual - Revised April 2000
DBS-2.3/9.2-300
Trunk and Line Expansion
Guidelines
• The EC/TRK slot can be used for a trunk or extension card. 
• Different expansion connectors are used for trunks and extensions:
Note: With the DBS 96, the expansion connector is not required to use 
the EC/TRK slot for an extension card. The DBS 96 uses connector CN14 
to accommodate an extension card in the EC/TRK slot. Table 4-22 on 
page 4-35 shows t
he pinouts from the EC/TRK slot to CN14.
Installation
1.  Install a trunk or extension card in the slot marked EC/TRK.
2.  Connect the appropriate expansion connector to the main cabinet with 
3.  Connect the ground cable from the FG terminal of the expansion 
connector to a screw already in use on the right side of the main cabinet.
4.  Connect CN2 of the expansion connector to CN15 on the mother board.
5.  Prepare a cable with a 50-pin connector on one end and wiring for the 
MDF on the other end.  
6.  Cross-connect the cable to the trunks or extensions through the MDF. See 
7.  Connect the 50-pin connector to CN1 on the expansion connector.   
Expansion connector
Part No.
Trunk expansion connector
VB-43120
Extension expansion connector 
VB-43121