Repair
334599A
5
Repair
Trigger Lock
Always engage the trigger lock when sprayer
is stopped to prevent the gun from being
triggered accidentally by hand or if dropped
or bumped. 
Pressure Relief Procedure
1.
Engage trigger lock.
2.
Turn ON/OFF switch to OFF position. 
Wait 7 seconds for power to dissipate. 
3.
Unplug power cord or shut engine off.
4.
Engage trigger lock.
5.
Remove tip guard.
This equipment stays pressurized until 
pressure is manually relieved. To help 
prevent serious injury from pressurized 
fluid, such as skin injection, splashed fluid 
and moving parts, follow the Pressure 
Relief Procedure whenever sprayer is 
stopped and before sprayer is cleaned or 
checked, and before equipment is 
serviced.
ti24612a
ti24851a
ti24852a
ti24853a