Motorola CDMA-EVDO REV A Manual De Usuario

Descargar
Página de 214
7 - 12 MC75 User Guide
Cables
Magnetic Stripe Reader
Table 7-7    
Troubleshooting the Cables
Symptom
Possible Cause
Action
MC75 battery is not 
charging.
MC75 was 
disconnected from 
AC power too soon.
Connect the power cable correctly. Confirm main battery is charging 
under 
Start
 > 
Settings
 > 
System
 > 
Power
. The 3600 mAh battery 
fully charges in less than six hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty 
battery.
The MC75 is not 
fully attached to 
power.
Detach and re-attach the power cable to the MC75, ensuring it is 
firmly connected. 
During data 
communication, no 
data transmits, or 
transmitted data was 
incomplete.
Cable was 
disconnected from 
MC75 during 
communications.
Re-attach the cable and retransmit.
Incorrect cable 
configuration.
See the system administrator.
Communication 
software is not 
installed or 
configured properly.
Perform setup as described in the MC75 Integrator Guide.
Table 7-8    
Troubleshooting the Magnetic Stripe Reader
Symptom
Possible Cause
Action
MSR cannot read 
card.
MSR removed from 
MC75 during card 
swipe.
Reattach MSR to MC75 and reswipe the card.
Faulty magnetic 
stripe on card.
See the system administrator.
MSR application is 
not installed or 
configured properly.
Ensure the MSR application is installed on the MC75.