Chapter 6: Troubleshooting 
45 of 60 
 
Chapter 6:  Troubleshooting 
6-1 Introduction 
The utmost in safety precautions should be observed at all times when working on or around 
the machine and the electrical components. All normal trouble-shooting must be 
accomplished with the power off, line fuses removed, and with the machine tagged as out of 
service.  
The use of good quality test equipment cannot be over-emphasized when troubleshooting is 
indicated. Use a good ammeter that can measure at least twice the AC and DC current that 
can be encountered for the machine. Be sure that the voltmeter has at least minimum 
impedance of 5,000 OHMS-per-volt on AC and 20,000 OHMS-per-volt on DC scales. 
Popular combination meters, VOM and VTVM can be selected to provide the necessary 
functions. 
Before making haphazard substitutions and repairs when defective electrical components are 
malfunctioning, we recommend that you check the associated circuitry and assemblies for 
other defective devices. It is common to replace the obviously damaged component without 
actually locating the real cause of the trouble. Such hasty substitutions will only destroy the 
new component. Refer to wiring diagrams and schematics. 
Locating mechanical problems, should they occur, is relatively straightforward. When 
necessary, refer to the parts catalog section. 
Figure 53: Typical Troubleshooting Problems and Suggested Corrective Actions 
Problem  
Corrective action 
Check to make sure that air is hooked up and the regulator gauge 
reads at precisely 60 PSI. 
 
Nothing happens when I start 
the extruder 
Look on the Recipe Screen.  If you don’t see a displayed Extruder 
RPM then check the inductive proximity switch.  If you do see a 
displayed RPM then check the hopper’s calibration 
“Interface has been Locked” is 
shown 
Click “Unlock” and enter in your User Password. 
I’ve forgotten my User 
Password 
Contact the Service Department. 
PLC Battery Low 
Change out the PLC with your spare and reprogram new unit.  
Send old PLC back to Manufacturer for repair.