Cisco Systems Linksys PAP2 Manual De Usuario

Descargar
Página de 117
 
 
 
 
CPC Delay
3,4
Delay in seconds after caller hangs up when 
the PHONE ADAPTER will start removing the 
tip-and-ring voltage to the attached equipment 
of the called party. 
Range= 0 to 255(s) 
Resolution = 1 (s) 
 2 
CPC Duration
3,4
Duration in seconds for which the tip-to-ring 
voltage is removed after the caller hangs up. 
After that tip-to-ring voltage is restored and dial 
tone will apply if the attached equipment is still 
off hook. CPC is disabled if this value is set to 
0. 
Range= 0 to 1.000 (s) 
Resolution = 0.001 (s) 
 0 
(CPC 
disable
d) 
 
Notes: 
1.  The Call Progress Tones and DTMF playback level are not affected by the <FXS Port Output 
Gain>. 
2.  The interdigit timer values are used as defaults when dialing. The Interdigit_Long_Timer is used 
after any one digit, if all valid matching sequences in the dial plan are incomplete as dialed. The 
Interdigit_Short_Timer is used after any one digit, if at least one matching sequence is complete 
as dialed, but more dialed digits would match other as yet incomplete sequences. 
3.  PHONE ADAPTER has had polarity reversal feature since release 1.0 which can be applied to 
both the caller and the callee end. This feature is generally used for answer supervision on the 
caller side to signal to the attached equipment when the call has been connected (remote end 
has answered) or disconnected (remote end has hung up). This feature should be disabled for 
the called party (ie by using the same polarity for connected and idle state) and the CPC feature 
should be used instead. 
4.  Without CPC enabled, reorder tone will is played after a configurable delay. If CPC is enabled, 
dial tone will be played when tip-to-ring voltage is restored. 
 
 
4.10.5. Miscellaneous 
Parameters 
 
Parameter Name 
Description 
Type 
Default 
Set Local Date 
(mm/dd/yyyy) 
Setting the local date; year is optional and 
can be 2-digit or 4-digit 
Str10  
Local Time (HH/mm/ss)  Setting the local time; second is optional. 
Str8 
 
Time Zone 
Number of hours to add to GMT to form local 
time for caller-id generation.  Choices: GMT-
12:00, GMT-11:00,…, GMT, GMT+01:00, 
GMT+02:00, …, GMT+13:00 
Choice GMT-07:00 
FXS Port Impedance 
Electrical impedance of the FXS port. 
{600,  
900, 600+2.16uF, 
900+2.16uF, 
270+750||150nF, 
220+820||120nF, 
220+820||115nF, 
370+620||310nF} 
600 
FXS Port Input Gain 
Input Gain in dB. Valid values are 6.0 to –
infinity. Up to 3 decimal places 
dB -3 
FXS Port Output Gain 
Similar to <FXS Port Input Gain> but apply to 
the output signal 
dB -3 
 
© 2004 Linksys Proprietary (See Copyright Notice on Page 2) 
 
 
 
76