Intel 8XC196MD Manual De Usuario

Descargar
Página de 579
C-19
REGISTERS
EPAx_CON
3
RE
Re-enable 
Re-enable applies to the compare mode only. It allows a compare event 
to continue to execute each time the event-time register (EPA
x
_TIME) 
matches the reference timer rather than only upon the first time match.
0 = compare function is disabled after a single event
1 = compare function always enabled
2
WGR
AD
Waveform Generator Reload; A/D Conversion
The function of this bit depends on the EPA channel.
For EPA capture/compare channels 0, 2, 4:
The WGR bit allows you to use the EPA activities to cause the reload 
of new values in the waveform generator.
0 = no action
1 = enables waveform generator reload
For EPA capture/compare channels 1, 3, 5:
The AD bit allows you to use the EPA activities to start an A/D 
conversion that has been previously set up in the A/D control 
registers.
0 = causes no A/D action
1 = starts an A/D conversion on an output compare
1
ROT
Reset Opposite Timer
Controls different functions for capture and compare modes.
In Capture Mode:
0 = causes no action
1 = resets the opposite timer
In Compare Mode:
Selects the timer that is to be reset if the RT bit is set.
0 = selects the reference timer for possible reset
1 = selects the opposite timer for possible reset
The TB bit (bit 7) selects which is the reference timer and which is the 
opposite timer.
EPA
x
_CON (Continued)
x
 = 0–1 (8XC196MH)
x
 = 0–3 (8XC196MC)
x
 = 0–5 (8XC196MD)
Address:
Reset State:
Table C-4
The EPA control (EPA
x
_CON) registers control the functions of their assigned capture/compare 
channels. 
7
0
x
 = 0, 2, 4
TB
CE
M1
M0
RE
WGR
ROT
ON/RT
7
0
x
 = 1, 3, 5
TB
CE
M1
M0
RE
AD
ROT
ON/RT
Bit
Number
Bit 
Mnemonic
Function