4.7.3 TS-1000 Loop Back Test 
The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media 
Converter devices. To assure the Remote TS-1000 OAM function can work correctly. 
 
In-band and out-band Loop back 
1. Instruct center Media Converter to issue an OAM frame to request a loop back test. Terminal return start response 
    OAM frame to center Media Converter. 
2. Terminal Media Converter runs at loop back mode. 
3. Central Media Converter send test frame and terminal Media Converter loop back the frames. Test frame can be   
    generated from central Media Converter’s UTP port (Out-Band) or from central Media Converter (In-Band)   
    automatically. 
4. Center Media Converter check the loop back test result after sending all test frames 
5. Instruct the central Media Converter to end loop back test. 
This function provides TS-1000 Loop Back Test of Managed Media Converter. Press the “Apply” button to run Loop Back 
Test and see the TS-1000 Loop Back Test Result of Managed Media Converter, also press the “Refresh” button to renew 
the Web screen. The screen in 
Figure 4-38 
appears and 
Table 4-14
 describes the TS-1000 Loop Back Test object of 
Managed Media Converter. 
 