Guardian Technologies 5308 Manual De Usuario

Descargar
Página de 90
section 5
tRoublesHooting FloWcHaRts
Page 32
BAD
REPAIR 
WIRING
GOOD
BAD
TEST 21 - 
CHECK 10 
AMP FUSE
TEST 26 - CHECK 
STARTER 
CONTACTOR 
RELAY (SCR)
TEST 27 - CHECK 
START-RUN-STOP 
SWITCH (SW1)
GOOD
TEST 28 - CHECK 
START-RUN-STOP 
SWITCH (SW1) 
WIRING
TEST 22 - CHECK 
BATTERY 
& CABLES
TEST 23 - CHECK 
VOLTAGE AT 
STARTER 
CONTACTOR
REPLACE FUSE
FUSE BLOWS
REPAIR OR 
REPLACE WIRING 
OR SCR
REPAIR OR 
REPLACE WIRE 16
REPLACE
BAD
BAD
REPLACE
GO TO PROBLEM 9
GOOD
GOOD
NO VOLTAGE 
MEASURED
FUSE BAD
BAD
TEST 24 - CHECK 
STARTER 
CONTACTOR
GOOD
12 VDC 
MEASURED
BAD
RECHARGE OR REPLACE BATTERY
- CLEAN, REPAIR OR REPLACE BAD 
CABLE(S)
TEST 25 - CHECK 
STARTER MOTOR
REPLACE STARTER 
MOTOR IF DEFECTIVE
GOOD
CHECK FOR 
MECHANICAL BINDING 
OF THE ENGINE OR 
ROTOR
Problem 6 -  Engine Will Not Crank