Guardian Technologies 5308 Manual De Usuario

Descargar
Página de 90
TEST 34 - TEST START STOP RELAY WIRINg
PROCEDURE:
1. Set voltmeter to the diode test range.
2. Disconnect Wire 229 from the Start Stop Relay (SSR).
3. Connect  the  positive  meter  test  lead  to Wire  229  previous-
ly  removed.  Connect  the  negative  meter  test  lead  to  frame
ground.  See  Figure  6-47.  Place  the  Start-Run-Stop  Switch  to
the  start  position. The  meter  should  read  approximately  1.0
VDC. If the correct voltage is indicated, stop testing.
1.0 vdc
SSR
15B
14
13
9
10
12
5
1
2
6
4
8
229
0
18
14
15
15
15
Figure 6-47. – Testing Wire 229 to Ground
4. Set voltmeter to measure resistance.
5. If voltage was not measured in Step 3 connect one meter test
lead  to Wire  229  removed  from  the  SSR.  Connect  the  other
meter  test  lead  to Wire  229  at  the Terminal  Block  1  (TB1).
Continuity  should  be  measured.  If  continuity  is  not  measured
repair or replace Wire 229 between SSR and TB1. Remove the
J2 connector the printed circuit board. Connect one meter test
lead  to  pin  location  J2-8  (Wire  229)  connect  the  other  meter
test lead to Wire 229 at TB1. See Figure 6-48. Be careful not
to  damage  the  pin  connectors  with  the  test  leads.  Continuity
should  be  measured.  If  continuity  is  not  measured  repair  or
replace Wire 229 between the J2 connector and TB1.
RESULTS:
1. If Step 3 passed refer to Flow Chart.
2. If Step 3 failed and Step 5 passed replace the printed circuit
board.
TB1
J2 HARNESS CONNECTOR
00.00
86
15B
167
BLK
0
229
83
BLK
TR2
TR1
J2-1
J2-12
MAKE SURE THE TEST 
PROBE CONNECTOR IS 
MAKING CONTACT 
WITH THE CONNECTOR. 
DOUBLE CHECK TO 
MAKE SURE THAT THE 
TIP IS SHARP.
Figure 6-48. – Testing Wire 229 Between J2 
Connector and Terminal Block 1 (TB1)
TEST 35 - CHECk ANd AdJUST IgNITION 
MAgNETOS
PROCEDURE:
1. See Figure 6-49. Rotate the flywheel until the magnet is under
the module (armature) laminations.
2. Place  a  0.008-0.012  inch  (0.20-0.30mm)  thickness  gauge
between the flywheel magnet and the module laminations.
3. Loosen the mounting screws and let the magnet pull the mag-
neto down against the thickness gauge.
4. Tighten both mounting screws.
5. To remove the thickness gauge, rotate the flywheel.
6. Repeat the above procedure for the second magneto.
7. Repeat Test  29  and  check  for  spark  across  the  spark  tester
gap.
8. If  air  gap  was  not  out  of  adjustment,  remove  engine  ground
harness from magnetos. Repeat Test 29. If sparking now occurs
replace engine ground harness.
section 6
Diagnostic tests
Page 56