Chapter 4: Operation 
 
LGC300A-R2 
724-746-5500   |   blackbox.com 
Page 11
 
4. Operation 
4.1 LED Operation 
 
The Industrial SFP/SFP contains four 
status LED indicators.  Each LED is 
dual color and has three states: off, red, 
or green.  A loss of signal on one SFP 
causes the TX of the other SFP to turn 
off.  This action does not activate the 
red TX Fault LED. 
 
LED 
Color or State 
Red 
OFF 
Green 
PWR
 
Card does not pass 
the self-test. 
Unit does not 
have power. 
Power is applied to the 
card. 
All internal self-test 
functions must pass 
before the PWR LED is 
green. 
SD I 
SD 2 
LED transmitter has 
an active fault. 
No active fault 
on transmitter. 
 
LOS indication 
on receiver. 
Valid signal is detected 
by the SFP and LED 
transmitter is not in 
fault. 
 
MSA 
LEDs 
One or both SFPs 
are not installed or 
not detected.  The 
TX inhibit must not 
be active if a SFP is 
missing.*  Or, both 
SFPs are installed, 
but their speed 
settings are 
different. This 
condition disables 
both SFPs. 
N/A 
Indicates that both 
SFPs with the same 
speed are securely 
installed. 
 
 
* To help in troubleshooting, the Link Loss (LL) feature is always ON.  That is, if a 
LOS is detected on an incoming SFP port, the Optical transmitter on the other SFP 
port is turned OFF.  This provides a Link Loss carry forward function to alert the 
device downstream of the existing problem.  This function is "ON" in both directions 
at the same time.  The LL function is inhibited if either SFP is not installed.