Graco TI12553a Manual De Usuario

Descargar
Página de 134
Color Change
312779E
113
F
IG
. 125: Color Change Chart 17
Valve
Time-Sequence
Dump A
A
Dump B
B
Color Change Solvent
Catalyst Change Solvent
Color Change A
A
A
Catalyst Change B
B
B
Air Purge
Solvent Purge
3rd Flush Purge
*Exiting Fill
Dispense A
A
A
Dispense B
B
B
Gun Trigger(s) by Operator
0
1
2
3
*Exiting Fill Time 0->2
Color Fill Time 0->1
Catalyst Fill Time 1->2
Mixed Fill Time 2->3
Notes:
Load tables from new recipe
Mixed Material Purge Timers from old recipe
CC Purge/Fill Timers and Mixed Fill Time from new recipe
*Exiting Fill Source and Length are Programmable
ProMix 2KS Recipe Change
Chart 17:  Recipe 0 OR 61 to Recipe X with Dump Valves and 3rd Flush Valve
Mixed Fill Time does not 
begin until the Exiting Fill 
Time and Color/Catalyst Fill 
Time is complete.
F
IG
. 126: Color Change Chart 18
Valve
Time-Sequence
Dump A
A
Dump B
Color Change Solvent
Catalyst Change Solvent
Color Change A
A
A
Catalyst Change B
Air Purge
Solvent Purge
3rd Flush Purge
*Exiting Fill
Dispense A
A
A
A
Dispense B
B
B
Gun Trigger(s) by Operator
0
1
2
3
*Exiting Fill Time 0->1
Color Fill Time 1->2
Mixed Fill Time 2->3
Notes:
Load tables from new recipe
Mixed Material Purge Timers from old recipe
CC Purge/Fill Timers and Mixed Fill Time from new recipe
*Exiting Fill Source and Length are Programmable
ProMix 2KS Recipe Change
Chart 18:  Recipe 0 OR 61 to Recipe X without Dump Valves and 3rd Flush Valve