Setup Mode 
44
312779E
NOTE: Each screen displays the current screen number 
and the total number of screens in the group. The total 
number of screens in a group and the fields displayed 
on each screen may vary depending on selections 
made in thSystem Configuration Screens an
Option Screens
Recipe Setup Screen 1
Ratio
Enter the mix ratio of component A over component B 
(0.0:1 to 50:1).
Ratio Tolerance
Enter the ratio tolerance (1 to 99%). This refers to the 
percent of acceptable variance that the system will allow 
before a ratio alarm occurs.
Component A (Color) Valve (if present)
This field only appears if the system includes a color 
change module. Enter the color valve number (1 to 30).
Component B (Catalyst) Valve (if present)
This field only appears if the system includes a color 
change module. Enter the catalyst valve number (1 to 
4).
Recipe Setup Screen 2
Minimum Flush Volume
This field only appears if Flush Volume Check is set to 
“On” in Option Screen 1 on page 36. Enter the mini-
mum flush volume (0 to 999 cc). Entering 0 disables this 
function.
Potlife Time
Enter the potlife time (0 to 999 minutes). Entering 0 dis-
ables this function.
Color/Catalyst Purge
This field only appears if the system includes a color 
change module and Flush and Fill Input is set to “Rec-
ipe” in Option Screen 1, page 36. Enter the purge time 
(0 to 99 seconds). It refers to the amount of time 
required to flush the lines from the color or catalyst mod-
ule to the dose valve or dump valve.
Color/Catalyst Fill
This field only appears if the system includes a color 
change module and Flush and Fill Input is set to “Rec-
ipe” in Option Screen 1, page 36. Enter the fill time (0 
to 99 seconds). It refers to the time required to fill the 
lines from the color or catalyst module to the dose valve 
or dump valve.