Graco TI12553a Manual De Usuario

Descargar
Página de 134
Integrated Flow Control
312779E
79
Result of the Test
Cause
Solution
Gauge reading increases and 
decreases as % Open value is 
changed and fluid flow does not 
change or is not present.
The problem is mechanical: 
restriction/plugged hose
plugged gun tip
fluid regulator failure
1.
Clear any clogs.
2.
Remove restrictions.
3.
Clean and/or repair fluid regula-
tor. 
Gauge reading does not increase 
and decrease as % Open value is 
changed.
The problem is electrical:
Fuse F2 is blown
disconnected wires or cables
pressure control failure
V/P valve failure
flow control board failure
1.
Measure the voltage to the regu-
lator at one of two places:
At J5 on the fluid control 
board, measure across the 
white (pin 1) and black (pin 6) 
wire connections. The volt-
age should be in the range of 
0-3.3 Vdc for 0%-100% Open 
command (approximately 
1.65 Vdc for 50% Open). 
At J2 on the flow control 
board of the module, mea-
sure across the red (pin 1) 
and black (pin 2) wire con-
nections. The voltage should 
be in the range of 0-21 Vdc 
for 0%-100% Open com-
mand (approximately 12 Vdc 
for 50% Open).
2.
If voltage is not present, check if 
fuse F2 on the fluid control board 
is blown.
3.
If voltage is present, ensure the 
cable is properly connected to 
the module circuit board.
4.
If cable is properly connected, 
replace pressure control, VP 
valve, and flow control board 
sequentially to isolate failure. See 
manual 3A2097.