System Operation 
88
312779E
Mix Manifold Valve Settings
To open dose or purge valves, turn hex nut (E) 
counter-
clockwise. To close, turn clockwise. See Table 13 and 
F
IG
. 99.
Table 12: Dynamic Dosing Troubleshooting Guide
(for complete system troubleshooting, see Table 17 beginning on page 116)
Warning/Alarm Message
Solution
B Pressure Too Low (see F
Increase B pressure.
Clean restrictor or use a larger size.
Verify B valve is opening properly.
B Pressure Too High
Increase A pressure or decrease B pressure.
Use a smaller restrictor.
Off Ratio Low
Increase A pressure or decrease B pressure.
Use a smaller restrictor.
Off Ratio High
Increase B pressure.
Clean restrictor or use a larger size.
Verify B valve is opening properly.
F
IG
. 99. Valve Adjustment
E
TI11581a
Table 13: Mix Manifold Valve Settings
Valve
Setting
Function
Dose (see 
F
IG
. 99)
Hex nut (E) 1-1/4 turns out 
from fully closed
Limits maximum fluid flow rate into integrator 
and minimizes valve response time.
Purge (see 
F
IG
. 99)
Hex nut (E) 1-1/4 turns out 
from fully closed
Limits maximum fluid flow rate into integrator 
and minimizes valve response time.
Shutoff (SVA 
and SVB, 
see F
Fully open during Run/Mix 
operation
Closes component A and B ports to integrator 
during ratio check or meter calibration. Open 
ports during Run/Mix operation.
Sampling 
(RVA and 
RVB, see 
F
Fully closed during Run/Mix 
operation
Open to dispense component A and B while 
calibrating meters. Do not open sampling 
valves unless fluid shutoff valves are closed.