Installation
3A0869H
21
Grounding
Connect the ProMix 2KE ground wire to the ground 
screw. Connect the clamp to a true earth ground. If wall 
power is used to power controls, ground electrical con-
nection according to local codes.
Gun Flush Box
Connect a ground wire from the Gun Flush Box ground 
lug to a true earth ground.
Flow Meters
Verify that the meter cables are connected as shown in 
the Hazardous Location Electrical Schematic on 
page 74-75. Failure to properly connect the shield may 
cause incorrect signals.
NOTE: The Coriolis meter can be used only on non-IS 
systems 24F080-24F083. When installed on these sys-
tems, the meter’s hazardous location intrinsically safe 
status is voided.
Feed Pumps or Pressure Pots
Connect a ground wire and clamp from a true earth 
ground to the pumps or pots. See pump or pressure pot 
manual.
Air and Fluid Hoses
Use grounded hoses only.
Spray Gun
Non-Electrostatic: Ground the spray gun through 
connection to a Graco-approved grounded fluid sup-
ply hose.
Electrostatic: Ground the spray gun through con-
nection to a Graco-approved grounded air supply 
hose. Connect the air hose ground wire to a true 
earth ground.
Fluid Supply Container
Follow local code.
Object Being Sprayed
Follow local code.
All Solvent Pails Used When Purging
Follow local code. Use only conductive metal pails/con-
tainers placed on a grounded surface. Do not place the 
pail/container on a nonconductive surface, such as 
paper or cardboard, which interrupts the grounding con-
tinuity.
Check Resistance
The equipment must be grounded. Grounding 
reduces the risk of static and electric shock by 
providing an escape wire for the electrical current 
due to static build up or in the event of a short circuit.
F
IG
. 11. Ground Screw and Power Switch
AC 
Power 
TI15712a
Ground 
Screw
To ensure proper grounding, resistance between 
components and true earth ground must be less than 
1 ohm.