Manual De UsuarioTabla de contenidosCisco SFS 3012R Multifabric Server Switch Hardware Installation Guide1Prefacevii3chapter 13CiscoSFS3012R Server Switch Overview1-13chapter 24Installing and Booting the CiscoSFS3012R Server Switch2-14chapter 34Installing and Removing Server Switch Field Replaceable Units (FRUs)3-14chapter 44Viewing and Updating the Software Image4-14chapter 55CiscoSFS3012R Server Switch LEDs5-15appendix A5Specifications and ComplianceA-15Index5Preface7Audience7Organization7.7Conventions8Statement 1071—Warning Definition9Related Documentation14Obtaining Documentation15Cisco.com15Product Documentation DVD15Ordering Documentation15Documentation Feedback16CiscoProduct Security Overview16Reporting Security Problems in CiscoProducts16Product Alerts and Field Notices17Obtaining Technical Assistance17CiscoTechnical Support & Documentation Website17Submitting a Service Request18Definitions of Service Request Severity18Obtaining Additional Publications and Information19Introduction21Figure1-1 CiscoSFS3012R Server Switch Chassis - Front View (Bezel End)21Features22Performance22Unified Fabric22Transparent Topology22Redundancy and High-Availability22Figure1-2 Fully Redundant System Architecture23Scalability23CiscoSFS3012R Server Switch Chassis24Figure1-3 CiscoSFS3012R Server Switch Chassis - Back View (cable End) with Slot Numbers24Figure1-4 CiscoSFS3012R Server Switch Chassis, Front View, Bezel Removed25CiscoSFS3012R Server Switch Components25Controller Modules25Figure1-5 CiscoSFS3012R Server Switch Controller Module26Ethernet and Fibre Channel Gateways27Figure1-6 Ethernet Gateway Expansion Module27Figure1-7 Fibre Channel Gateway Expansion Module28InfiniBand Switch Modules29Figure1-8 InfiniBand Switch Module29Power Supply Modules30Figure1-9 Power Supply Module30Blower Modules31Figure1-10 Blower Module31Safety33Preparing for Installation35Step1 Remove all components from the CiscoSFS3012R Server Switch shipping container, and ident...35Step2 Place the chassis on a secure, clean surface.35Step3 Verify that you have a CiscoSFS 7008 InfiniBand and CiscoSFS 3012 Multifabric Server Swi...35Step4 Verify that you have at hand all Ethernet gateways and Fibre Channel gateways that you wil...35Step5 Prepare a management workstation (not included), such as a PC running terminal-emulation s...35Installing CiscoSFS3012R Server Switch Components35Mounting the CiscoSFS3012R Server Switch on a Rack36Step1 Open the plastic bag that contains the mounting hardware.36Step2 Attach the rack-mounting brackets to the sides of the chassis with the screws provided, as...36Figure2-1 Positioning and Fastening the Rack-Mounting Brackets and Shelf Rails36Step3 Attach the shelf rails to either side of the CiscoSFS3012R Server Switch chassis as foll...37Step4 Mount the shelf onto the rack, as shown in Figure2-2, using the procedure outlined below....37Figure2-2 Attaching the Shelf to the Rack37Step5 Slide the CiscoSFS3012R Server Switch onto the shelf, as shown in Figure2-3. Engage the...38Figure2-3 Positioning and Sliding the Chassis onto the Shelf38Step6 Adjust the cable end of the shelf that you left loose in Step4 so that the holes in rack-...38Step7 Use 4 standard rack screws (not included) to secure the rack-mounting brackets to the rack...39Figure2-4 Securing the Chassis to the Rack39Step8 Firmly tighten the shelf screws at the cable end.39Attaching a Serial Console Cable to a PC or Terminal40Step1 Connect the cable from the serial console port on the controller module to your terminal o...40Step2 Open a terminal emulation window using a program such as HyperTerminal for Windows. Set yo...40Booting the CiscoSFS3012R Server Switch and Configuring Basic Connectivity40Step1 Connect a power cord to your CiscoSFS3012R Server Switch, and then plug the cord into an...40Step2 After the system boots, press the Enter key several times to display the CLI login prompt.40Step3 Enter super as your user ID and password to log in as a user with administrative privileges.40Assigning a Static IP Address41Step1 Attach an Ethernet cable (not provided) from the management port to the Ethernet router or...41Step2 Enter the enable command.41Step3 Enter the configure command.41Step4 Enter the interface mgmt-ethernet command.41Step5 Enter the IP address of the management port followed by the net mask, as shown in this exa...41Step6 Set the default gateway of the management port, as shown in this example:41Step7 Enable the management port with the no shutdown command.41Step8 Save the configuration to preserve it between reboots.41Obtaining an IP Address with DHCP41Step1 Attach an Ethernet cable (not provided) from the management port to the Ethernet router or...41Step2 Enter the enable command.41Step3 Enter the configure command.41Step4 Enter the interface mgmt-ethernet command.42Step5 Enter the addr-option dhcp command to configure the chassis to obtain the IP address from ...42Step6 Enable the management port with the no shutdown command.42Step7 Save the configuration to preserve it between reboots.42Step8 Enter the show interface mgmt-ethernet command to determine your IP address, as shown in t...42Connecting InfiniBand Hosts42Figure2-5 InfiniBand Cable with Pinch Connector43Figure2-6 InfiniBand Cable with Pull Connector43Figure2-7 Removing a Pinch Connector44Figure2-8 Removing a Pull Connector44Managing the CiscoSFS3012R Server Switch44Installing a Controller Module46Step1 Ground yourself with an approved ground wrist strap.46Step2 Remove the blanking panel if one resides in the slot.46Step3 Remove the controller module from any packaging.46Step4 Extend the ejector lever on the module completely.46Step5 Insert the controller module into slot 1 (left-most) or slot 14 (right-most) so that the e...46Step6 Push the controller module firmly into the slot. The ejector lever begins to close.46Figure3-1 Inserting the Controller Module46Step7 Push the ejector lever up until it clicks into place, as shown in Figure3-2.47Figure3-2 Closing the Ejector Lever47Adding or Replacing Ethernet or Fibre Channel Gateways47Step1 Ground yourself using an approved ground wrist strap.47Step2 Remove the blanking panel if one resides in the slot.47Step3 Remove the gateway module from any packaging.47Step4 Extend the ejector lever on the gateway completely.47Step5 Insert the gateway into an expansion module slot such that the ejector lever sits on the b...47Step6 Push the gateway module firmly into the slot. The ejector lever begins to close.48Step7 Push the ejector lever up until it clicks into place.48Step8 Follow the procedures in Chapter4, “Viewing and Updating the Software Image” to update or...48Installing an InfiniBand Switch Module48Step1 Ground yourself using an approved ground wrist strap.48Step2 Remove the blanking panel if one resides in the slot with a number 1 Phillips-head screwdr...48Step3 Remove the switch module from any packaging.48Step4 Extend the ejector levers on the left-hand side and on the right-hand side of the switch m...48Step5 Insert the switch module into slot 15 or slot 16 such that the ejector levers sit on the b...48Step6 Press the switch module firmly into the slot so the fasteners begin to close, as shown in ...49Figure3-3 Inserting a Switch Module49Step7 Close both fastener levers simultaneously and completely.49Figure3-4 Closing Switch Ejector Levers49Step8 Tighten the screws on either side of the switch module to secure it to the chassis.50Figure3-5 Securing an InfiniBand Switch Module50Step9 Verify that the system image on the InfiniBand switch module is consistent with the image ...50Removing an InfiniBand Switch Module51Step1 Make sure the CiscoSFS3012R Server Switch chassis is securely seated in the rack.51Step2 If you are removing the InfiniBand module from slot 16 (the lower module), you must power ...51Step3 Properly ground yourself to avoid potential electrostatic discharge and damage to the module.51Step4 Facing the cable end of the CiscoSFS3012R Server Switch chassis, unfasten both screws on...51Step5 Open both ejector levers simultaneously, and pull the switch module toward you.51Step6 Either replace the module immediately or install a blanking panel over the empty chassis b...51Installing a Power Supply Module51Step1 Ground yourself using an approved ground wrist strap.52Step2 Remove the blanking panel if one resides in the slot.52Step3 Remove the power supply module from any packaging.52Step4 Insert the power supply into an open slot such that the pull handle sits toward the outsid...52Step5 Press the power supply firmly into the chassis.52Removing a Power Supply Module53Step1 Ground yourself using an approved ground wrist strap.53Step2 Remove the power cord from the power supply.53Step3 Disengage the power supply by pulling it toward you.53Step4 Slide the power supply out of the chassis.53Step5 Either replace the power supply immediately or fasten a blanking panel to the empty chassi...53Installing a Blower Module53Step1 Ground yourself using an approved ground wrist strap.53Step2 Remove the blower module from any packaging.53Step3 Insert the blower module into an open slot until it is fully seated so that the captive sc...54Figure3-6 Inserting a Power Supply54Step4 Tighten the captive screw on the front panel to secure the module to the chassis, as shown...54Figure3-7 Securing a Blower Module54Removing a Blower Module55Step1 Ground yourself using an approved ground wrist strap.55Step2 Unfasten the captive screw.55Step3 Pull the blower module toward you until it completely disengages from the chassis.55Step4 Insert a replacement blower module into the empty chassis bay to ensure appropriate cooling.55Viewing the Software Image Version57Viewing the Software Image Version with the CLI58Step1 To view the primary software image version for all cards in the chassis, use the show card...58Step2 Use the dir image command to view all existing boot images on the chassis, and determine w...58Viewing the Software Image Version with the Element Manager GUI59Step1 Launch Element Manager.59Step2 View the software version of the controller:59Figure4-1 Viewing the Software Image Version of the Controller Module59Step3 View the software version on individual cards in the chassis:60Figure4-2 Viewing Current Image of an Individual Module60Updating the Software Image60Updating the Software Image with the CLI61Step1 Copy the image to the chassis controller.61Step2 Activate the image. After downloading the image file to the chassis controller, you must i...61Step3 Specify the new boot image to be used.61Step4 Reboot the chassis using the reload command.62Step5 Save the system configuration when prompted, and confirm that you wish to proceed with the...62Step6 Following reboot, use the show card-inventory command to view the new primary image for al...62Updating the Software Image with the Element Manager GUI62Step1 Launch the Element Manager GUI.62Step2 Select Maintenance > File Management. The File Management window appears.62Step3 Click the Import button.63Figure4-3 Copying an Image File to the Server Switch63Step4 Click the Copy button to copy the file onto the controller of the sever switch. Wait until...64Step5 Activate the image. After downloading the image file to the chassis controller, it must be...64Step6 Specify the new boot image to be used.64Figure4-4 Specifying the Boot Configuration64Step7 Reboot the chassis.64Deleting a Software Image65Deleting an Image with the CLI65Deleting an Image with the Element Manager GUI66Step1 Select Maintenance > File Management.66Step2 Click on the .img file that you want to delete, as shown in Figure4-5.66Figure4-5 Deleting an Image File66Step3 Click the Delete button.66Step4 Click Yes in the Delete file? dialog box.66CiscoSFS3012R Server Switch System Status LED68Figure5-1 Location of System LED68Table5-1 System Status LED Indications68Power Supply LEDs69Figure5-2 Power Supply LEDs69Table5-2 AC Power Supply LED69Table5-3 DC Power Supply LED69Blower Module LEDs70Figure5-3 Blower Module LEDs70Table5-4 Blower LED Indications70Controller LEDs71Figure5-4 Controller LEDs71Table5-5 Controller Status LEDs71Table5-6 Blower Status LEDs71Table5-7 Power Status LEDs72Figure5-5 Location of Management Ethernet Port LEDs72Table5-8 Management Ethernet LED Indications72InfiniBand LEDs73Figure5-6 InfiniBand Switch Module and InfiniBand Port LEDs73InfiniBand Switch Module LEDs73Table5-9 Infiniband Switch Module LED Indications73InfiniBand Port LEDs74Table5-10 Management Ethernet LED Indications74Fibre Channel LEDs75Figure5-7 Location of Fibre Channel Gateway and Fibre Channel Port LEDs75Fibre Channel Gateway LEDs75Table5-11 Gateway LED Indications75Fibre Channel Port LEDs76Table5-12 Interpreting the Fibre Channel Port Status LEDs76Table5-13 Interpreting the Fibre Channel Port Activity LEDs76Ethernet Gateway LEDs77Figure5-8 Location of Ethernet Gateway and Ethernet Port LEDs77Ethernet Gateway LEDs78Table5-14 Ethernet Gateway LED Indications78Ethernet Port LEDs78Table5-15 Ethernet Port LED Indications78A79Specifications and Compliance79General Specifications79TableA-1 General Specifications79Electrical Specifications80TableA-2 Electrical Specifications80Certifications/Regulatory80TableA-3 Certifications/Regulatory80Laser Specifications80TableA-4 Laser Specifications80A81B81C81D81E81F82G82H82I82L82P82R83S83T83Tamaño: 7 MBPáginas: 84Language: EnglishManuales abiertas