Peerless Industries SUA746PU Manuel D’Utilisation

Page de 29
5 of 29
ISSUED: 10-24-11  SHEET #: 095-9364-1
Place wall arm (A) on wall as template, level, 
and mark the center of two mounting holes. Top 
mounting hole will be 6.66" above the center of 
display mounting plate as shown in fi gure 1.1 on 
page 4. Drill two 5/16" dia. holes to a minimum 
depth of 2.5". Insert anchors (D) into holes fl ush 
with wall as shown. Secure wall arm (A) to wall with 
two wood screws (C) as shown in fi gure 1.3. For 
cable management option, install cable anchor (I) to 
bottom mounting hole with wood screw (C).
NOTE: Be sure arrow is pointing up when mounting 
wall arm assembly (A) to wall as shown in fi gure 
1.1. Level, then tighten all fasteners.
Insert two fastener caps (H) into wall plate mounting 
holes.
D
SOLID CONCRETE
CINDER BLOCK
1
Installation to Solid Concrete or Cinder Block
CUT
A
W
A
Y
 VIEW
INCORRECT
CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
•  When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual 
concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount 
in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM 
C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a 
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
•  Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•  Make sure that the supporting surface will safely support the combined load of the equipment and all attached 
hardware and components.
 WARNING
•  Tighten screws so that wall plate is fi rmly attached, 
but do not overtighten. Overtightening can damage 
screws, greatly reducing their holding power.
•  Never tighten in excess of 80 in. • lb (9 N.M.).
•  Always attach concrete expansion anchors directly 
to load-bearing concrete.
•  Never attach concrete expansion anchors to 
concrete covered with plaster, drywall, or other 
fi nishing material. If mounting to concrete surfaces 
covered with a fi nishing surface is unavoidable (not 
evaluated by UL), the fi nishing surface must be 
counterbored as shown below. Be sure concrete 
anchors do not pull away from concrete when 
tightening screws. If plaster/drywall is thicker than 
5/8" (16 mm), custom fasteners must be supplied by 
installer (not evaluated by UL).
 WARNING
A
C
H
I
fi g. 1.3
1
3
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
2
D
A
C
concrete
surface