Emerson MMI-20011276 Manuel D’Utilisation
4
Micro Motion
®
Series 3000 MVD Transmitters
NOC Overview
2.2.1
NOC system components
The Series 3000 MVD NOC system requires:
•
One Series 3000 MVD transmitter with the Net Oil Computer software option
•
One Micro Motion sensor installed on the oil/water or oil leg
Optional components include:
•
A meter on the gas leg. This meter can be used for gas measurement with or without Transient
Mist Remediation:
Mist Remediation:
-
If only gas measurement will be implemented, either a third-party meter or a
Micro Motion meter may be used. Gas measurement must be based on mass flow.
Micro Motion meter may be used. Gas measurement must be based on mass flow.
-
If Transient Mist Remediation will be implemented, a Micro Motion meter must be used.
•
A water cut monitor on the oil/water or oil leg.
•
A pressure sensor on the oil/water or oil leg. Data from the pressure sensor enables pressure
compensation (see Section 2.3.2).
compensation (see Section 2.3.2).
2.2.2
Installation architecture
The Series 3000 MVD NOC system is designed for installation with a three-phase separator, a
two-phase separator, or a variety of compact separators. See Figures 2-1 through 2-3.
two-phase separator, or a variety of compact separators. See Figures 2-1 through 2-3.
Note: These figures do not illustrate all possible combinations.