Emerson 3414 Manuel D’Utilisation
16
Meter specifications
Section 1: Introduction
Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual
June 2014
3-9000-759 Rev D
Communications specifications
Connectivity protocols
One serial RS-232/RS-485 port (115 kbps baud rate) (Modbus RTU/ASCII)
•
(1) Serial Port A
(RS-232/RS-485 Full Duplex/RS-485 Half Duplex)
(RS-232/RS-485 Full Duplex/RS-485 Half Duplex)
One Ethernet Port (TCP/IP) 100 Base
•
Up to 10 Mbps (internal connection) 100Mbps (external connection)
•
Modbus TCP, TCP/IP
Device compatibility
Daniel Ultrasonic flow meters are compatible with nearly every commercially available flow
computer. Examples: FloBoss 103, FloBoss S600 flow computer, ROC 107,
computer. Examples: FloBoss 103, FloBoss S600 flow computer, ROC 107,
Digital, analog, and frequency inputs
Digital Input(s)
(Selectable)
(Selectable)
(1) Single polarity
—
Four pulse configurations available
Analog Input(s)
(2) 4-20 mA
•
AI-1 Temperature
•
AI-2 Pressure
Note: The analog-to-digital conversion accuracy is within ±0.05% of full scale over the operating
temperature range.
Note: AI-1 and AI-2 are electronically isolated and operate in sink mode. The input contains a series
resistance so HART® Communicators can be connected to configure sensors.
A 24 Volt DC power output is available to provide power to the sensors.
Table 1-2 Meter specifications