STARTUP FOR SYSTEMS USING EXPLOSION-PROOF CONDUIT
Section 3: Electrical installation
Daniel 3410 Series Ultrasonic Gas Flow Meter Installation Manual
June 2014
3-9000-759 Rev D
Figure 3-4  Transmitter electronics field wiring lower terminal block    
F.
      
G.
    
H.
A.  Upper terminal block
 
B.  FODO Group 1 connections
 
FODO1
GND1
DI 1
E. Ethernet 
Ethernet (orange and white wire)
Ethernet (orange wire)
Ethernet (green and white wire)
Ethernet (green wire)
C. AO1
      AO1+
      AO1 -
D. Serial COMs (RS-232, RS-485)
     RS-232: RTS, TX, RX, CTS
      RS-485: TX+, TX -, RX+, RX - (4-wire Full Duplex )
B.
C.
D.
E.
A.
     RS-485: TX+, TX- (2-wire Half Duplex)
F.  24V loop power  (4-24mA  inputs/outputs)
G.  Power In (104VDC - 36VDC)
H. Fuse cover