Configuring an M3UA System on a Signaling Gateway
180
Smart Media Software Configuration Guide 
5 • Configuring SIGTRAN Applications
Creating an M3UA Configuration (SGP)
To set up your M3UA system on a signaling gateway process (SGP), you must first create a new M3UA config-
uration. In this configuration the SS7 MTP2 layer is replaced entirely by the SIGTRAN M3UA layer, and the 
MTP3 layer is extended over the IP network. To create an M3UA configuration on an SGP:
1. Select M3UA from the navigation panel:
Figure 298. SS7 > M3UA
2. Configure the M3UA service for SGP:
– Enter  a  name for the configuration
– Select Signaling Gateway Process (SGP) as the node type
– Click Create
Figure 299. Creating the New M3UA (SGP) Configuration
3. Verify that the "M3uaCfg was successfully updated" message displays.
Figure 300. Successful Configuration Message
Understanding Parameters for M3UA Configurations
Table 69. Configuration Parameters for New M3UA Configurations
Parameter
Description
Name
Used by the Web Portal to indicate a specific object or string in the system
Node Type
Assigns a configuration to an M3UA network. Possible values:
Signaling Gateway Process (SGP)
Application Server Process (ASP)
IP Server Process (IPSP)