VIZIO C-RM1000 CU Manuel D’Utilisation

Page de 60
35
11.3.3. To reset alarm
Hold down the RESET key for 2 seconds or more while alarm
is being activated. 
The RESET key extinguishes, canceling the alarm mode.
BUZZER STOP
RESET
BUZZER STOP
RESET
11.3.4. Putting screen switching on hold when an alarm occurs
When an alarm occurs, the screen display is automatically switched from the camera images through Monitor
Output 1 to the alarm triggered camera images in full-screen. Press the HOLD key to put the current screen
display on hold, disabling automatic screen switching.
Notes
• Camera shift to the preset position programmed on the Digital Video Recorder is also put on hold. Alarm
action programmed on the Combination Camera cannot be put on hold.
• When digital video recorders are connected to remote controllers in cascade, the display on the master
monitor cannot be retained.
1. Press the HOLD key.
The HOLD key lights, putting the automatic screen
switching to the alarm-triggered screen display on hold.
Note
The screen cannot be switched due to alarm signal
reception, alarm reset nor elapse of Digital Video
Recorder's pre-set time while the Hold key lights.
2. Hold down the HOLD key for 2 seconds or more. 
The HOLD key extinguishes, enabling automatic screen
switching when an alarm signal is received.
HOLD
Lights
HOLD
HOLD
Extinguishes
HOLD
11.3.2. To stop a buzzer tone
Press the RESET key to stop the buzzer tone.
BUZZER STOP
RESET
11.4. Joystick Position Adjustment
Adjusts the joystick's central position.
1. Switch off the remote controller's power.
2. Press the power switch to turn on the power while holding down both the "Full Screen" and "Auto" keys.
The remote controller judges the current joystick's position as center. 
Note: Avoid turning the power switch to on with the joystick tilted.