Maha Energy D1 3602BA1-GB03 Manuel D’Utilisation

Page de 26
Trucklift  
Maintenance, Troubleshooting 
18 
D1 3602BA1-GB03 
 
Problem Possible 
cause 
Remedy 
The lift stops at a height of 
approx. 260 mm 
(measured from the floor to 
the lower edge of the 
carriage).
 
The lift can only be 
lowered from this position. 
Further raising is not 
possible. 
The LED on the circuit 
board blinks.(see ill. on 
next page 
a) The distance between the  
    catch nuts and the jackscrew  
    bearing nuts is too small. 
b) A proximity switch is defective  
    or its setting is incorrect. 
a) Check the wear of the bearing  
    nuts. 
b) Check the distance between  
    the proximity switches and the  
    switching cams on the frame  
    and on the catch nuts .5 mm). 
The lift stops at a height of 
approx. 400 mm 
(measured from the floor to 
the lower edge of the 
carriage).
 
The lift can only be 
lowered from this position. 
Further raising is not 
possible. 
The LED on the circuit 
board blinks.(see ill. on 
next page)  
No signal pulse from the 
switching cam on the frame or 
the catch nut. 
Check the proximity switches. 
(Call MAHA-Service Dept.). 
Check the distance between the 
proximity switches and the 
switching cams on the frame 
and on the catch nuts. 
The lift can only be moved 
to its lower starting 
position. 
Lifting is no longer 
possible. 
A bearing nut is broken and the 
load is being borne by the catch 
nut. 
Have the bearing nut repaired. 
 
Shut down the lift and 
lock the main switch! 
At the beginning of lifting 
the lift stops and the power 
supply circuit breaker trips. 
Neither lifting nor lowering 
are possible. 
All motors are starting up 
simultaneously. This causes a 
voltage peak that trips the circuit 
breaker  
DIP switch 4 is set to "ON".(see 
ill. on next page) 
Change the setting of DIP switch 
4 on the control PCB to 
"OFF".(see ill. on next page). 
This starts the motors in a 
staggered sequence.