Sterling AF-XXX Manuel D’Utilisation

Page de 55
Additive Feeders 
Chapter 4: Operation 
26 of 55 
7.   Install the enclosure cover. 
8.  Remove any lockout/tagout devices in use as per procedures in place at your 
facility, then connect the controller to the power source and power the unit 
up. 
 
9.  Press the Enter button until parameter selection mode is entered.  When the 
drive is in Parameter-Selection Mode, the far left of the display will be a “P.” 
 
10.  Use the Up and Down arrow buttons to navigate to the desired parameter. 
 
11.  When the parameter number to be changed is displayed press the Enter 
button to enter Value Mode. When in Value Mode, the two dots which form 
the colon between digits two and three will alternately flash. 
 
12.  Use the Up and Down arrow buttons to change the parameter’s displayed 
value. 
 
13.  Press the Enter button to return to Parameter-Selection Mode. 
  
14.  Use the Up and Down Arrow buttons to go to the next parameter to be 
modified.  Repeat as required for any remaining parameters. 
 
15.  When all program modifications are completed, use the Up and Down Arrow 
buttons to go to parameter “0” then press the Enter button to return to run 
mode. 
 
16.  Remove the power source from the controller.  Following the procedures in 
your facility, lockout or tagout the power source. 
 
17.  Remove the dust cover from the control enclosure. 
 
18.  At the connection end of the drive lift the black plastic cover up slightly then 
slide it out of the back of the drive. 
 
19.  Locate the jumper labeled “JP1”. 
 
20.  Move the JP1 jumper from the “ON” position to the “OFF” position. 
 
21.  Slide the black plastic cover back into position. 
 
22.   Install the enclosure cover. 
 
23.  Remove any lockout/tagout devices in use as per procedures in place at your 
facility, then connect the controller to the power source and power the unit 
up. 
 
The drive is now ready to be used. 
 
The required programming values for Injection Mold Applications are located on 
drawing number A0541236, one of three drawings that are included with the additive