TANDBERG 2200 Manuel D’Utilisation

Page de 142
 
118 
• 
22 - local use 6 (local6) 
• 
23 - local use 7 (local7) 
Using syslog 
The events that are forwarded to the syslog receiver hosts are controlled by the capture filter. 
To define a syslog server, simply enter its IP address and then click 
Update syslog settings
. The number of packets sent 
to each configured host is displayed next to its IP address.  
Note
: Each event will have a severity indicator as follows:  
• 
0 - Emergency: system is unusable (unused by the IP VCR) 
• 
1 - Alert: action must be taken immediately (unused by the IP VCR) 
• 
2 - Critical: critical conditions (unused by the IP VCR) 
• 
3 - Error: error conditions (used by IP VCR error events) 
• 
4 - Warning: warning conditions (used by IP VCR warning events) 
• 
5 - Notice: normal but significant condition (used by IP VCR info events) 
• 
6 - Informational: informational messages (used by IP VCR trace events) 
• 
7 - Debug: debug-level messages (used by IP VCR detailed trace events)