TANDBERG 2200 Manuel D’Utilisation
118
•
22 - local use 6 (local6)
•
23 - local use 7 (local7)
Using syslog
The events that are forwarded to the syslog receiver hosts are controlled by the capture filter.
To define a syslog server, simply enter its IP address and then click
Update syslog settings
. The number of packets sent
to each configured host is displayed next to its IP address.
Note
: Each event will have a severity indicator as follows:
•
0 - Emergency: system is unusable (unused by the IP VCR)
•
1 - Alert: action must be taken immediately (unused by the IP VCR)
•
2 - Critical: critical conditions (unused by the IP VCR)
•
3 - Error: error conditions (used by IP VCR error events)
•
4 - Warning: warning conditions (used by IP VCR warning events)
•
5 - Notice: normal but significant condition (used by IP VCR info events)
•
6 - Informational: informational messages (used by IP VCR trace events)
•
7 - Debug: debug-level messages (used by IP VCR detailed trace events)