TROUBLESHOOTING
SYMPTOM 
 
 
 
PROBABLE CAUSE 
 
 
REMEDY 
Move unit to a well ventilated 
area.
Repair or replace gaskets.  Torque 
head bolts to 17ft./lbs.  
Contact motor repair center.
Push the Motor/Pressure Switch  
to the "OFF" position.  If the motor 
does not shut off, unplug the air 
compressor.  If the electrical con-
tacts are welded together, replace 
the pressure switch.
Limit the air pressure to the ca-
pacity of the air compressor.  Ei-
ther use a smaller tool or a larger 
air compressor.
Motor Thermal Overload con-
tinues to trip or fails to reset.
Motor runs continuously.
Improper ventilation causing the pump 
or motor to overheat.
Defective head gasket or faulty (reed) 
valve.
Faulty motor Thermal Overload.
Motor Pressure Switch does not shut 
off motor when air compressor reaches 
"Stop" pressure and safety relief valve 
activates.
 
Air compressor is incorrectly sized.
Air compressor starts but 
does not build up pressure.
Tighten connection.
Air bleed off line is loose.
Air Tank Drain Valve is open.
Air leaks at connections.
Completely close Air Tank Drain 
Valve.
Allow the air compressor to build 
pressure to the maximum allowed.  
Turn off and brush a soapy water 
solution onto all connections.  
Check connections for air bubbles.  
Tighten the connections where 
leaks are present.
Air leak in air tank.
Air tank must be replaced. 
 Do not 
attempt to repair air tank!
Defective Check Valve.   
Remove, clean or replace.
Pressure loss in system.